FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
333495-YTG-D-0609
TECHNICAL GUIDE
Description
These York
®
Affinity packaged heat pumps are designed for
outdoor installation. Only utility and duct connections are
required at the point of installation.
Field-installed electric heater accessories are available to
provide electric heat, if required.
R-410A
AFFINITY™ SERIES
BHX, BHQ AND BHZ MODELS
2 - 5 TON
60 Hertz
Tested in accordance with:
ISO 9001
Certified Quality
Management System
Question and Answer IconNeed help?

Do you have a question about the York Affinity BHZ060 and is the answer not in the manual?

York Affinity BHZ060 Specifications

General IconGeneral
Cooling Capacity (BTU/h)60, 000
Heating Capacity (BTU/h)60, 000
RefrigerantR-410A
SEER RatingUp to 16
Compressor TypeScroll
Voltage208/230
Phase1
ModelBHZ060
Number of Stages1

Summary

Technical Guide Overview

Product Description

Explains the purpose and application of the packaged heat pumps for outdoor installation.

Component Identification

Heat Pump Components

Illustrates the internal components of the heat pump unit with labels.

Nomenclature and Key Features

Model Number Breakdown

Explains the structure of the model identification codes for the units.

Standard Features Overview

Details the primary features and benefits of the heat pump units.

Detailed Unit Features

Design and Appearance Features

Covers aesthetics, coil protection, sound muffling, and fan system operation.

Operational and Control Features

Details control circuits, compressor protection, pressure switches, and system integration.

Maintenance and Durability Features

Highlights coil design, low maintenance aspects, and service access points.

Field Installed Accessories

Introduces optional accessories for enhanced functionality like economizers and hail guards.

Accessory Kits and System Specifications

Specific Accessory Kits

Describes specific accessory kits like timers, filter kits, dampers, thermostats, and transformer kits.

Guide Specifications: General

Outlines manufacturing standards, unit description, and certifications.

Guide Specifications: Cabinet and Fans

Details unit cabinet construction and indoor/outdoor fan assembly specifications.

Guide Specifications: Components

Refrigerant, Coils, and Safety

Specifies refrigerant circuit components, coil construction, and safety features.

Electric Heating Section Details

Describes the field-installable electric heating accessory and its specifications.

Physical Data

BHZ024-060 Model Specifications

Provides detailed physical specifications including dimensions, weight, and component data.

Unit Limitations

Operating Voltage and Temperature Ranges

Lists the operational voltage and outdoor temperature limits for different models.

Cooling Capacity Performance Tables

BHZ024-060 Cooling Capacities Overview

Presents comprehensive cooling performance tables for various airflow and temperature conditions.

BHZ024 (2.0 Ton) Cooling Data

BHZ030 (2.5 Ton) Cooling Data

BHZ030 (2.5 Ton) Cooling Data Continued

BHZ036 (3.0 Ton) Cooling Data

BHZ036 (3.0 Ton) Cooling Data Continued

BHZ042 (3.5 Ton) Cooling Data

BHZ042 (3.5 Ton) Cooling Data Continued

BHZ048 (4.0 Ton) Cooling Data

BHZ048 (4.0 Ton) Cooling Data Continued

BHZ060 (5.0 Ton) Cooling Data

BHZ060 (5.0 Ton) Cooling Data Continued

Heating Capacity Performance Tables

BHZ024-060 Heating Capacities

Provides heating capacity tables for various airflow and temperature conditions.

BHZ024-060 Heating Data Continued

BHZ024-060 Heating Data Continued

External Static Pressure Performance

BHZ024-060 Static Pressure Data

Details airflow and static pressure relationships for various speeds and models.

BHZ024-060 Static Pressure Data Continued

Additional Static Resistance Values

Component Resistance Data

Lists resistance values for coils, economizer, filters, and electric heat.

Electric Heat and Blower Specifications

Minimum Supply Air for Electric Heat

Specifies minimum airflow requirements for electric heat operation based on kW.

Blower Specs and Heat Multipliers

Covers indoor blower specifications and electric heat multiplier data for voltage adjustments.

Sound Performance Data

Outdoor Sound Power Levels by Octave Band

Presents sound level data in octave bands for different models and conditions.

Electrical Data

Unit Electrical Specifications and Ratings

Provides detailed electrical data including MCA, Max Fuse/Breaker, and motor ratings.

Wiring Diagrams

BHX024, 048, 060 208/230-1-60V Wiring Diagram

Shows a specific wiring diagram for a 208/230-1-60 volt configuration.

BHZ024-060 230-60V Wiring Diagram

Displays a wiring diagram for a 230-60 volt configuration.

BHZ030-060 230-3-60V Wiring Diagram

Presents a wiring diagram for a 230-3-60 volt 3-phase configuration.

BHZ030-060 460-3-60V Wiring Diagram

Shows a wiring diagram for a 460-3-60 volt 3-phase configuration.

Weights and Dimensions

Unit Weights and Load Distribution

Details shipping and operating weights, plus 4-point load locations for various models.

Accessory Unit Weights

Lists weights for optional accessories like economizers and electric heat.

Overall Unit Dimensions

Key Dimensions and Clearances

Provides key height dimensions for different models and lists required installation clearances.

Unit Dimension Views

Front, Bottom, Back, and Side Views

Illustrates dimensional details from front, bottom, back, and side views of the unit.

Typical Installation Configurations

Duct Application Examples

Shows common roof curb duct connection methods (rear and bottom).

Slab on Ground Installation Example

Illustrates a typical ground installation setup with wiring connections.