333495-YTG-C-0908
4 Johnson Controls Unitary Products
• More Attractive Appearance - A single piece Water 
Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation 
and provides a wider variety of installations. The one 
piece design adds greater water integrity. Rounded 
corners with water drip edges add to the attractive 
appearance. The cabinet panels have a non-fibrous 
insulation that will not release insulation fibers into 
conditioned area.
• Top Discharge - The top discharge condenser fan does 
not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted 
fan is blown up away from the structure and any 
landscaping. This allows compact location on multi-unit 
applications.
• Condenser Coil Grille - A multi-piece totally enclosed, 
rigidly mounted condenser coil grille provides protection 
from objects after installation and provides protection 
during transit.
• Low Operating Sound Level - The upward air flow 
carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds. The unique 
formed base pan also aids in sound alterations with it's 
Super-Structure design. This design strategically places 
embossments in the pan for optimum strength and rigidity.
• Fan System - All models operate over a wide range of 
design conditions with an electrically commutated fan 
motor. These units easily match all types of applications 
and provide greater on site flexibility to match comfort 
requirement. The cooling speed is factory set and can be 
field adjusted to a second speed. The heating speed is 
factory set to maintain mid point rise at the units heating 
input, but can be field adjusted. This allows maximum 
comfort conditions.
• Simple Control Circuit - A low voltage printed circuit 
board contains a diagnostic indicator light and a low 
voltage terminal strip. An additional set of pin connectors 
is also provided to simplify the field interface of external 
controls. Mate-n-lock plug connectors are used. The 
electrical control box is not located in the compressor 
compartment. The controls are mounted on a Control-Tilt 
control panel to allow the access cover to be removed for 
trouble shooting and maintenance without affecting the 
normal system operating pressures. All wiring internal to 
the unit is color/number coded.
• Protected Compressor - The compressor is internally 
protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which 
protect the compressor if undesirable operating conditions 
occur.
• Pressure Switches - High pressure and low pressure/
loss of charge switches standard in all units. When 
abnormal conditions are sensed through the pressure 
switches, the unit will lock out preventing any further 
operation until reset or problem is corrected. 
• Exclusive Coil Design - Grooved copper tubes and 
enhanced aluminum fin construction improves heat 
transfer for maximum efficiency and durability.
• Low Maintenance - Long life, permanently lubricated 
condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit. 
Blower assembly can be easily cleaned by the unique 
Slip- Track slide-out blower assembly.
• Secured Service Access Ports - Protected, externally 
mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.
•
Easy Service Access - A large, single panel covers the 
electrical and gas controls makes servicing easy. The 
blower compartment has an additional large panel with a 
built-in handle tab. Removing this panel will allow the 
blower assembly to slide-out for easy removal for 
maintenance and ease of trouble shooting.
• Replacement Parts - The installer requires no special 
training to replace any of the components of these units 
and does not need to maintain an inventory of unique 
parts.
• System Integration - Each unit has the internal ability to 
integrate an electronic air cleaner or humidifier to work in 
conjunction with the base unit.
Field Installed Accessories
• Economizer Down Discharge/Supply Kit - Modulating 
integrated economizer provides simultaneous operation 
between the mechanical cooling and economizer 
operation. Independent blade design insures proper 
control and less than 1% leak rate. Includes hood and 
mesh bird screen filter integrated into the hood, dry bulb 
sensor and relief damper. Separate field accessories of 
single enthalpy and dual enthalpy are also available. A 
built-in barometric relief of 25% is provided.
• Single Enthalpy Sensor - Sensor replaces dry bulb 
sensor standard in economizer kit. Provides improved 
economizer operation by sensing the dry bulb 
temperature from outdoors plus the enthalpy content of 
the outdoor air.
• Dual Enthalpy Sensor - Additional sensor to single 
enthalpy sensor. Sensor senses both the return air 
temperature dry bulb and humidity in conjunction with the 
single enthalpy to determine the most economical mix. 
Single Enthalpy sensor also required.
• Hail Guard Kit - Kit contains protective grilles made of 
expanded aluminum with full perimeter frame. Sloped 
hoods are also included to assure maximum protection.
• Anti Short Cycle Timer (BHZ Units Only) - 
Automatically prevents the compressor from restarting for 
5 minutes after cycled off.Not required if Thermostat