Do you have a question about the York AHR30B3XH21 and is the answer not in the manual?
Phase | 1 |
---|---|
Refrigerant | R-410A |
Cooling Capacity | 30000 BTU |
HSPF Rating | 9 |
Voltage | 208-230V |
Heating Capacity | 30000 BTU |
Overview of single-piece air handlers for split-system cooling and heat pumps, covering models AHR18 through AHR60.
Details key product features like thermal expansion valve, insulated cabinet, and factory sealed construction, plus general description.
Outlines the standard 5-year and extended 10-year limited parts warranty terms.
Provides physical dimensions (A-F) and wiring knockout locations (J, K) for various air handler models.
Details coil size, face area, rows, fins per inch, tube geometry, diameter, and fin type for each model.
Presents cooling capacity (MBH) data for various models under different entering air conditions and R-410A pressures.
Details capacity factors based on the percentage of rated airflow (CFM) for system optimization.
Lists physical attributes like blower size, motor HP/RPM, voltage, amps, and filter types for cooling operations.
Provides conversion factors for adjusting kW and MBH data based on distribution power.
Details motor FLA, minimum circuit ampacity, MOP, and minimum wire size for cooling applications.
Specifies minimum fan speed (Low, Med, High) for electric heater kits with air handler models.
Provides performance data (kW, MBH) for electric heat kits across staging options (W1 Only, W1+W2).
Details minimum circuit ampacity, MOP, and wire size for electric heater kits with single-source power supply.
Provides electrical data (MCA, MOP, wire size) for multi-source power configurations with electric heat kits.
Details electrical requirements (MCA, MOP, wire size) for 3-phase single-source power for electric heater models.
Presents electrical data for 3-phase multi-source power, including MCA, MOP, and wire size.
Illustrates common airflow configurations like upflow, downflow, and horizontal for typical installations.
Lists available accessories like TXV kits and electric heaters, along with voltage and airflow limitations.
Shows wiring diagrams for thermostat connections for various cooling and electric heat configurations.
Illustrates wiring for a specific electric heat kit, including sequencer and motor connections.
Provides airflow (CFM) for models at different speeds and static pressures when operating at 208V.
Presents airflow (CFM) for models at different speeds and static pressures when operating at 230V.
Continues airflow (CFM) data for specific models at 230V across static pressures.
Contains copyright details, publication information, and superseding document references.