York AM024M1021 - COOLING CAPACITY - With Air Handler Coils; ACCESSORIES; SOUND RATINGS

York AM024M1021
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
036-21573-001 Rev. A (0304)
4 Unitary Products Group
- = Not applicable.
ACCESSORIES*
Refer to Price Manual for specific model numbers.
Hard Start Kit - Provides increased starting torque for areas
with low voltage.
Compressor Blanket - Designed to further reduce the nor-
mal compressor operating sound. Refer to price pages for
specific match-ups.
Off Cycle Timer Delay - Provides a 5-minute off cycle to pre-
vent rapid recycling of the compressor.
Room Thermostats - A wide selection of compatible thermo-
sets are available to provide optimum performance and fea-
tures for any installation.
1 Heat Stage only, manual, mechanical thermostat. Add sub-
base for 1H/1C.
1H/1C, manual change-over electronic non-programmable
thermostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the
price book or consult factory.
SOUND RATINGS*
*Rated in accordance with ARI Standard 270.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 10 SEER AC WITH N1AH / G2FD
AM012M1021 N1AHB0806 10 17 G2FD024(S,H)17 450 14.5 10.4 10.00 - 10.00
AM018M1021 N1AHB0806 10 17 G2FD024(S,H)17 650 18.6 13.4 10.00 - 9.50
AM024M1021 N1AHB0806 10 17 G2FD024(S,H)17 850 23.4 16.8 10.00 - 9.15
AM030M1021 N1AHB1206 10,15,18 17 G2FD030(S,H)17 1050 28.2 20.3 10.00 - 9.00
1 PH 10 SEER AC / F2RP
4
,
5
AM012M1021 F2RP018 2,5,8 18 - 500 14.5 10.6 10.00 - 9.70
AM018M1021 F2RP/F2FP018 2,5,8 18 - 650 17.4 12.6 10.00 - 9.35
AM018M1021 F2RP/F2FP024 5,8,10 18 - 650 18.6 13.4 10.00 - 9.50
AM024M1021 F2RP/F2FP024 5,8,10 18 - 850 23.4 16.8 10.00 - 9.15
AM030M1021 F2RP/F2FP030 5,8,10,15 18 - 1050 28.4 20.3 10.00 - 9.05
AM030M1021 F2RP/F2FP036 5,8,10,15,19 21 - 1050 29.0 20.7 10.00 - 9.15
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 95°F outdoor ambient, 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP
. All ratings remain the same.
5. F2RP air handlers have B.O.D (Blower on Delay) standard.
UNIT MODEL
SOUND
RATINGS
DBA
012 72
018 74
024 75
030 76