EasyManua.ls Logo

York D2CE 072 User Manual

York D2CE 072
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GENERAL
YORK Model DCE units are single package air conditioners
designed for outdoor installation on a rooftop or a slab. Electric
heaters are available as field-installed accessories.
The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and electrical
wiring is factory-installed and tested. The units require only
electric power and duct connections at the point of installation.
The electric heaters have nickel-chrome elements and utilize
single point power connection.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier’s freight bill. A separate
request for inspection by the carriers agent should be made in
writing. Refer to Form 50.15-NM for additional information.
REFERENCE
Additional information on the design, installation, operation and
service of this equipment is available in the following reference forms:
55.70-N1 -General Installation
55.70-N2 -Pre-start & Post-start Check List
530.18-N1.2V -Economizer Accessory
530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%
530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%
530.18-N1.12V -Motorized Outdoor Air Damper Accy..
530.18-N1.8V -Coil Guard
530.18-N7.1V -Electric Heater Accessory
530.18-N7.2V -Fuse Block Accessory
690.15-N25V -Low Ambient to 0
°
F
Renewal Parts:
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms referenced in this instruction may be ordered from:
Publications Distribution Center
Unitary Products Group
P.O. Box 1592, York, PA 17405
APPROVALS
Design certified by U.L. and C.G.A. as follows:
1. For use as a cooling only unit or cooling unit with electric heat.
2. For outdoor installation only.
3. For installation on combustible material.
®
SUNLINE 2000
ELECTRIC / ELECTRIC
SINGLE PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTION
Supersedes: 530.18-N7Y (993)
530.18-N7Y (295)
Installer should pay particular attention to the words:
NOTE, CAUTION
and
WARNING
. Notes are intended to clarify or make
the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury
and/or equipment damage may result if installation procedure is not handled properly.
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS
AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRI-
CAL, AND MECHANICAL CODES
WARNING
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE
PERSONAL INJURY, PROPERTY DAMAGE AND/OR DEATH.
WARNING
DE-ENERGIZE THE ELECTRICAL POWER TO THE UNIT BEFORE ATTEMPTING TO INSPECT, REPAIR OR PERFORM
MAINTENANCE TO THE UNIT.
035-12855
MODELS D4CE 036, 048 & 060 (10 SEER)
MODEL D2CE 072 (9 EER)
(STYLE B & Belt-Drive Option)
CAUTION
SCROLL COMPRESSORS
OPERATE IN ONLY ONE
DIRECTION.
If the compressor is
experiencing:
- low amperage draw
- similar discharge and
suction pressure
- increased noise level
It is operating in reverse.
Switch two line voltage
connections to correct.
Question and Answer IconNeed help?

Do you have a question about the York D2CE 072 and is the answer not in the manual?

York D2CE 072 Specifications

General IconGeneral
Model NumberD2CE 072
CategoryAir Conditioner
Tonnage6 Tons
Cooling Capacity72, 000 BTU/h
Refrigerant TypeR-410A
Voltage208/230V
Sound Level (Outdoor)76 dB
Phase3
Sound Level (Indoor)Not Applicable

Summary

Installation

Installation Limitations

Codes and conditions that must be followed for unit installation.

Installation Location

Recommended placement and site preparation for outdoor installation.

Clearances and Access

Required space around the unit for operation and servicing.

Ductwork Installation

Guidelines for connecting supply and return air duct systems.

Power and Control Wiring

Requirements for safe and compliant electrical field wiring.

Operation

Safety Controls

Explanation of safety devices like freezestat and pressure cutouts.

Maintenance

Normal Maintenance

Routine checks and cleaning for filters, motors, and coils.