LX SERIES
DUCTLESS SINGLE-SPLIT
AIR CONDITIONERS AND HEAT PUMPS
16 SEER – 1 PHASE
3/4 THRU 2 NOMINAL TONS
MODELS: DCMF/DHMF
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 2-Years limited parts warranty.
Standard 6-Years limited compressor warranty.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
923178-UTG-B-0114
DESCRIPTION
The Single-Split Series are ductless climate systems. They are
designed with a matching indoor unit for optimum performance and effi-
ciency. These climate systems are supported with accessories and doc-
uments to serve specific functions.
FEATURES
Variable Frequency Rotary Compressor - Twin rotary inverter compressor
on all models features high efficiency operation that modulates down to 15
Hz and as high as 120 Hz for reduced vibration and quiet operation. Brush-
less DC motor uses powerful Neodymium magnets that are approximately
15-20 times stronger than ferrite magnets used in conventional AC compres-
sors. The DC Inverter Control provides continuous operation, while adjusting
capacity according to room temperature. The accurate sensing of cooling or
heating loads prevents frequent changes in capacity and ensures efficient,
economical operation.
Low Ambient Cooling Operation Down to 5 °F - This feature allows for a
space to be air-conditioned even in outdoor temperatures as low as 5 °F.
This cooling ability is important when dealing with server equipment rooms,
surveillance mechanical rooms, restaurant kitchens, fitness centers, and
more.
Load Variation Management System - The outdoor coil thermistor continu-
ously monitors the temperature and communicates with the microprocessor.
Depending on the temperature measured, the compressor will be allowed to
increase the frequency if needed to meet the load or reduce frequency as
the load is reduced.
High Pressure Discharge Temperature - The compressor discharge line
thermistor continuously monitors the temperature and communicates with
the microprocessor. Depending on the temperature measured, the compres-
sor will be allowed to increase the frequency to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high, the compressor will be de-energized.
Defrost Control (Heat Pump Models) - Defrost cycle is automatically
enabled if there is a build-up of frost on the outdoor coil. Outdoor fan and
indoor blower operation is terminated during the defrost cycle. H1 is dis-
played on the indoor unit panel on the front cover during a defrost cycle.
Reversing Valve (Heat Pump Models) - 4-way interchange reversing valve
effects a rapid change in direction of refrigerant flow resulting in quick
changeover from cooling to heating and vice versa. Valve operates on sys-
tem pressure differential between outdoor unit and indoor unit.
R-410A Refrigerant - Unit is pre-charged with R410A refrigerant that uses
PVE refrigerant oil. Polyvinyl ether (PVE) is an innovative refrigerant oil spe-
cially formulated for hydrofluorocarbon (HFC) refrigeration systems. In addi-
tion to providing lubricating properties, it also has a number of other applied
advantages that help to increase the reliability of the refrigeration systems
where it is applied.
Refrigerant Line Connections, Service Valve - Outdoor units are designed
with easy service and maintenance in mind. Maintenance points are located
behind easy-access panels, to make installation and service a breeze for a
trained technician. Flare connection lines are located on side of unit cabinet.
Fully serviceable brass service valve prevents corrosion and provide access
to refrigerant system. Shut-off valve that can be fully shut off while 2-way
suction/vapor valve (with service port) may be front seated to manage refrig-
erant charge while servicing system.
Air Deflection Louvers - Horizontal louvers default to the cooling or heating
position when the unit is operating. Horizontal louvers can be set to a preset
oscillating range or fixed position from the wireless remote control. Full oscil-
lating is the default setting when button is pushed. Vertical louvers can be
manually adjusted to direct the airflow for optimal comfort.
Indoor Coil Freeze Protection - The indoor coil thermistor monitors the coil
temperature continuously. Any time the coil temperature drops below 30°F,
the compressor and the outdoor fan (30 seconds later) will be switched off
until the coil temperature rises above 43°F and the compressor has been off
for a minimum of 3 minutes.
I FEEL Function - When I FEEL is activated, the system will satisfy the cool-
ing or heating temperature setpoint where the remote control is located.
When I FEEL is deactivated, the system will satisfy the cooling or heating
temperature setpoint where the indoor unit is located. This feature provides
homeowners with optimum comfort whether they are near or far from the
indoor unit.
Hot Heat Pump (cold air prevention) - In heating mode, the indoor fan will
be delayed from 1 to 3 minutes to allow refrigerant to warm up and avoid
cold blow. This may occur during:
Initial start-up of a heating cycle
Immediately after completion of an Auto mode operation
Heating under extremely low indoor temperatures
Question and Answer IconNeed help?

Do you have a question about the York DHMF12CSM42Q1 and is the answer not in the manual?

York DHMF12CSM42Q1 Specifications

General IconGeneral
HSPF9
Phase1
Heating Seasonal Performance Factor (HSPF)9
Cooling Capacity (BTU/hr)12000
Voltage (V)208/230
Heating Capacity (BTU/h)12000
Power Supply208/230V, 1Ph, 60Hz
RefrigerantR410A

Summary

Description

Features

Variable Frequency Rotary Compressor

Twin rotary inverter compressor with high efficiency operation.

Low Ambient Cooling Operation

Allows cooling in outdoor temperatures as low as 5°F.

Load Variation Management System

Monitors outdoor coil thermistor for load adjustment.

High Pressure Discharge Temperature

Monitors compressor discharge line temperature for safety.

Defrost Control

Automatically defrosts outdoor coil in heating mode.

Reversing Valve

Enables quick changeover between cooling and heating.

R-410A Refrigerant

Uses R410A refrigerant and PVE oil for efficiency.

Refrigerant Line Connections

Features easy service access with flare connections.

Air Deflection Louvers

Controls airflow direction horizontally and vertically.

Indoor Coil Freeze Protection

Protects indoor coil from freezing by controlling compressor.

I FEEL Function

Senses temperature at the remote control for comfort.

Hot Heat Pump (Cold Air Prevention)

Delays indoor fan in heating mode to prevent cold drafts.

Nomenclature

Specifications

Air Conditioner Specifications

Detailed performance data for air conditioner models.

Heat Pump Specifications

Product Operation Characteristic Curves

Product Capacity Variation Ratio

Operation Data

Sound Data

Product Construction View & Dimensions

Indoor Unit Dimensions

Provides dimensions and gross weight for indoor units.

Outdoor Unit Dimensions

Provides dimensions and gross weight for outdoor units.

Refrigerant System Diagram

Wiring Diagram

Electrical Data

Lists symbols, color symbols, and part names for wiring.

Electrical Wiring Diagrams

Illustrates the electrical connections for indoor and outdoor units.

Description of Each Control Operation

Temperature & Current Parameters

Defines key parameters like preset, ambient, and coil temperatures.

Basic Functions

Explains compressor restart delay and minimum run time.

Cooling Mode Operation and Protection

Covers cooling operation, modes, and protection mechanisms.

AUTO Mode Operation and Protection

Details auto mode logic and protection based on ambient temp.

Dehumidification Mode Operation and Protection

Explains dehumidification sequences and safety controls.

Heating Mode Operation, Defrost, and Protection

Details heating sequences, defrost cycles, and protections.

Fan Mode Operation

Describes the operation of the unit in fan-only mode.

Common Protection Functions and Fault Display

Overload Protection (Tube Temperature)

Details protection based on tube temperature for overload conditions.

High Discharge Temperature Compressor Protection

Protects compressor from excessive discharge temperatures.

Communication Fault

Describes system stoppage due to communication loss.

Module and DC Bus Voltage Protection

Covers module protection, overload temp, and DC bus voltage faults.

Temperature Sensors Faults

Lists faults related to open or short-circuited temperature sensors.

Resistance Tables

Ambient Temperature Sensor Resistance Table (15K)

Provides resistance values for ambient sensors at various temperatures.

Tube Temperature Sensor Resistance Table (20K)

Provides resistance values for tube sensors at various temperatures.

Outdoor Discharge Temperature Sensor Resistance Table (50K)

Provides resistance values for outdoor discharge sensors.

Removal Procedure

Indoor Unit Removal Procedure

Step-by-step guide for disassembling the indoor unit.

Outdoor Unit Removal Procedure

Step-by-step guide for disassembling the outdoor unit.