LX SERIES
DUCTLESS MULTI-ZONE SPLIT
HEAT PUMPS
16 SEER – 1 PHASE
1.5 THRU 3.5 NOMINAL TONS
MODELS:
INDOOR-DHPM/OUTDDOR-DHMF
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 2-Years limited parts warranty.
Standard 6-Years limited compressor warranty.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
923212-UTG-A-0113
DESCRIPTION
The Multi Zone Series are ductless climate systems. They are designed
with a matching indoor unit for optimum performance and efficiency.
These climate systems are supported with accessories and documents
to serve specific functions.
FEATURES
Variable Frequency Rotary Compressor - Twin rotary inverter compressor
on all models features high efficiency operation that modulates down to 15
Hz and as high as 120 Hz for reduced vibration and quiet operation. Brush-
less DC motor uses powerful Neodymium magnets that are approximately
15-20 times stronger than ferrite magnets used in conventional AC compres-
sors. The DC Inverter Control provides continuous operation, while adjusting
capacity according to room temperature. The accurate sensing of cooling or
heating loads prevents frequent changes in capacity and ensures efficient,
economical operation.
Low Ambient Cooling Operation Down to 5 °F - This feature allows for a
space to be air-conditioned even in outdoor temperatures as low as 5 °F.
This cooling ability is important when dealing with server equipment rooms,
surveillance mechanical rooms, restaurant kitchens, fitness centers, and
more.
Condenser High Temperature Protection - The outdoor coil thermistor
continuously monitors the temperature and communicates with the micro-
processor. Depending on the temperature measured, the compressor will be
allowed to increase the frequency if needed to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high the compressor will be de-energized.
High Pressure Discharge Temperature - The compressor discharge line
thermistor continuously monitors the temperature and communicates with
the microprocessor. Depending on the temperature measured, the compres-
sor will be allowed to increase the frequency to meet the load or is forced to
run at the current or reduced frequency. If the temperature gets excessively
high, the compressor will be de-energized.
Defrost Control (Heat Pump Models) - Defrost cycle is automatically
enabled if there is a build-up of frost on the outdoor coil. Outdoor fan and
indoor blower operation is terminated during the defrost cycle. H1 is dis-
played on the indoor unit panel on the front cover during a defrost cycle.
Reversing Valve (Heat Pump Models) - 4-way interchange reversing valve
effects a rapid change in direction of refrigerant flow resulting in quick
changeover from cooling to heating and vice versa. Valve operates on sys-
tem pressure differential between outdoor unit and indoor unit.
R-410A Refrigerant - Unit is pre-charged with R410A refrigerant that uses
PVE refrigerant oil. Polyvinylether (PVE) is an innovative refrigerant oil spe-
cially formulated for hydrofluorocarbon (HFC) refrigeration systems. In addi-
tion to providing lubricating properties, it also has a number of other applied
advantages that help to increase the reliability of the refrigeration systems
where it is applied.
Refrigerant Line Connections, Service Valve - Outdoor units are
designed with easy service and maintenance in mind. Maintenance points
are located behind easy-access panels, to make installation and service a
breeze for a trained technician. Flare connection lines are located on side of
unit cabinet. Fully serviceable brass service valve prevents corrosion and
provide access to refrigerant system. Shut-off valve that can be fully shut off
while 2-way service valve (with service port) may be front seated to manage
refrigerant charge while servicing system.
Air Deflection Louvers - Horizontal louvers default to the cooling or heating
position when the unit is operating. Horizontal louvers can be set to a preset
oscillating range or fixed position from the wireless remote control. Full oscil-
lating is the default setting when button is pushed. Vertical louvers can be
manually adjusted to direct the airflow for optimal comfort.
Indoor Coil Freeze Protection - The indoor coil thermistor monitors the coil
temperature continuously. Any time the coil temperature drops below 30°F,
the compressor and the outdoor fan (30 seconds later) will be switched off
until the coil temperature rises above 43°F and the compressor has been off
for a minimum of 3 minutes.
I FEEL Function - When I FEEL is activated, the system will satisfy your
cooling or heating temperature setpoint where the remote control is located.
When I FEEL is deactivated, the system will satisfy the cooling or heating
temperature setpoint where the indoor unit is located. This feature provides
homeowners with optimum comfort whether they are near or far from the
indoor unit.
Hot Heat Pump (cold air prevention) - In heating mode, the indoor fan will
be delayed from 1 to 3 minutes to allow refrigerant to warm up and avoid
cold blow. This may occur during:
Initial start-up of a heating cycle
Immediately after completion of an Auto mode operation
Heating under extremely low indoor temperatures
Question and Answer IconNeed help?

Do you have a question about the York DHMF42CMM42Q1A and is the answer not in the manual?

York DHMF42CMM42Q1A Specifications

General IconGeneral
Phase1
RefrigerantR-410A
Cooling Capacity42000 BTU
HSPF9.0
Voltage208/230V
Heating Capacity42000 BTU
Heating Seasonal Performance Factor (HSPF)9
Power Supply208/230V, 1 Phase, 60Hz
Operating Temperature (Cooling)5°C to 43°C
Operating Temperature (Heating)-15°C to 24°C

Summary

DESCRIPTION

FEATURES

Nomenclature

SPECIFICATIONS

Performance

Detailed performance metrics for cooling and heating modes.

Indoor Unit Specification

Technical specifications for the indoor unit components.

Outdoor Unit Specification

PRODUCT OPERATION CHARACTERISTIC CURVES

PRODUCT CAPACITY VARIATION RATIO

SOUND DATA

INDOOR UNITS

Noise level data for indoor units at different fan speeds.

OUTDOOR UNITS

PRODUCT CONSTRUCTION VIEW & DIMENSIONS

Indoor Unit Dimensions

Physical dimensions and weight of the indoor unit.

Outdoor Unit Dimensions

Physical dimensions and weight of the outdoor unit.

WIRING DIAGRAM

Electrical Data

Symbol and color code mapping for wiring connections.

Electrical Wiring

18K Outdoor Heat Pumps

Wiring schematic for 18K model outdoor heat pumps.

24K Outdoor Heat Pumps

Wiring schematic for 24K model outdoor heat pumps.

Electrical Wiring Diagrams

30K Outdoor Heat Pumps

Wiring schematic for 30K model outdoor heat pumps.

42K Outdoor Heat Pumps

Wiring schematic for 42K model outdoor heat pumps.

DESCRIPTION OF EACH CONTROL OPERATION

System Basic Functions

Explains cooling, dry, and heating modes and their operations.

Protection Functions

Details safety features and protection mechanisms for the system.

RESISTANCE TABLES

Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units (15K)

Resistance values for ambient temperature sensors at various temperatures.

Resistance Table of Outdoor and Indoor Tube Temperature Sensors (20K)

Resistance Table of Outdoor Discharge Temperature Sensor (50K)

REMOVAL PROCEDURE

Removal Procedure of Indoor Unit

Step-by-step guide for safely disassembling the indoor unit.

Removal Procedure of Outdoor Unit

ACCESSORIES

OTHER ACCESSORIES

List of miscellaneous accessories for the unit.

MOUNTING ACCESSORIES

Accessories for mounting the unit and its components.

MINISPLIT LINESETS

Various linesets for connecting indoor and outdoor units.

LINESET COVERS AND FITTINGS

Covers and fittings for minsplit linesets.

NOTES

Related product manuals