Johnson Controls Unitary Products 7
923212-UTG-A-0113
OPERATION DATA
Notes:
Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor thermometer).
Connecting piping condition: 24.6 ft.
P: pressure of air pipe connected to the indoor and outdoor units (gas valve side),
T1: Inlet and outlet temperature for evaporator,
T2: Inlet and outlet temperature for condenser.
SOUND DATA
INDOOR UNITS
42K
Capacity Ratio (%)
Outdoor Temp (°F)
Heating
Cooling
Outdoor Temp (°F)
Capacity Ratio (%)
110
100
90
80
70
60
50
89.6
93.2 96.8 100.4
104.0
105.8
111.2 114.8
120
110
100
90
80
70
60
5.0
14.0 23.0
32.0
41.0
50.0
50
40
Temperature Condition (°F)
Model name
Standard
Pressure
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Frequency (Hz)
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
COOLING
80/66.9 95/75 18K(9K+9K) 0.9 to 1.1 50 to 55 150 to 104 Super High High 76
80/66.9 95/75 24K/30K(9K+9K+9K) 0.9 to 1.1 54 to 59 158 to 104 Super High High 70
80/66.9 95/75 42K 0.9 to 1.1 53.6 to 57.2 158 to 104 Super High High 75
HEATING
70/60 46.9/43 18K(9K+9K) 2.3 to 2.7 150 to 100 35 to 40 Super High High 76
70/60 46.9/43 24K/30K(9K+9K+9K) 2.3 to 2.7 150 to 100 35 to 40 Super High High 76
70/60 46.9/43 42K 2.3 to 2.8 158 to 95 33.8 to 41.0 Super High High 85
40
45
30
35
Indoor side noise when running
Indoor fan motor rotating speed
Low Middle High
Super High
Noise/dB(A)
12K
09K
09K/12K/18K Unit
50
55
40
45
35
Indoor side noise when running
Indoor fan motor rotating speed
Low Middle High
Super High
Noise/dB(A)
18K