Wiring diagrams (duct indoor unit type)
ENJC 09, 12, 18, 24, 30, 36, 42, 48 + EUKC 09, 12, 18, 24, 30, 36, 42, 48
ENJC 36, 42, 48, 60 + EUKC 36, 42, 48, 60
OUTDOOR UNIT INDOOR UNIT
OUTDOOR UNIT INDOOR UNIT
1 Power supply cable size outdoor unit
09k, 12k 3 x 2,5 mm
2
18k, 24k 3 x 4 mm
2
30k, 36k, 42k, 48k 3 x 6 mm
2
2 Power supply cable size indoor unit
12k, 18k 3 x 1,0 mm
2
24k, 30k, 36k, 42k, 48k 3 x 1,5 mm
2
3 Interconnection cables 2 x 0,25 mm
2
1 Power supply cable size outdoor unit 5 x 4 mm
2
2 Power supply cable size indoor unit 3 x 1,5 mm
2
3 Interconnection cables 2 x 0,25 mm
2
09k - 12k ----> CN3 outdoor unit / CN12 indoor unit
18k - 48k ----> CN66 outdoor unit / CN12 indoor unit
36k - 60k ----> CN66 outdoor unit / CN12 indoor unit