EasyManua.ls Logo

York GHGD18 - Page 6

York GHGD18
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
571921-UTG-A-0410
6 Johnson Controls Unitary Products
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
GHGD18S41S3
450 - 750 14,17 FC/MC/PC18 600 18.0 14.0 13.00 11.00
450 - 750 14,17 FC/MC/PC24 600 18.0 14.0 13.50 11.00
450 - 750 14 HC18 600 18.0 14.0 13.00 11.00
450 - 750 14 HD24 600 18.0 14.0 13.50 11.00
GHGD24S41S4
600 - 1000 14 FC/MC/PC32 800 23.8 17.1 13.00 11.00
600 - 1000 17,21 FC/MC/PC35 800 23.6 17.1 13.00 11.00
600 - 1000 14 FC/MC/PC37 800 24.0 17.3 13.00 11.00
600 - 1000 17,21 FC/MC/PC43 800 24.0 17.3 13.00 11.00
GHGD30S41S4
800 - 1200 14 FC/MC/PC32 1000 29.8 21.8 13.00 11.00
800 - 1200 17,21 FC/MC/PC35 1000 29.8 21.8 13.00 11.00
800 - 1200 14 FC/MC/PC37 1000 30.0 22.2 13.00 11.00
800 - 1200 17,21 FC/MC/PC43 1000 30.0 22.2 13.00 11.00
GHGD36S41S4
1000 - 1400 17,21 FC/MC/PC43 1200 36.0 26.6 13.00 11.00
1000 - 1400 14 FC/MC/PC37 1200 36.0 26.8 13.00 11.00
1000 - 1400 HD48 1200 36.0 26.4 13.00 11.00
1000 - 1400 21,24 FC/MC/PC48 1200 36.0 26.6 13.00 11.00
1000 - 1400 21,24 UC48 1200 36.0 26.8 13.00 11.00
GHGD42S41S4
1200 - 1600 21,24 FC/MC/PC60 1400 41.0 31.8 13.00 11.00
1200 - 1600 HD60 1400 41.0 31.4 13.00 11.00
1200 - 1600 21,24 UC60 1400 40.5 31.0 13.00 11.00
GHGD48S41S4
1400 - 1800 21,24 FC/MC/PC60 1600 44.0 33.4 13.00 11.00
1400 - 1800 24 FC/MC62 1600 44.5 33.8 13.00 11.00
1400 - 1800 21,24 UC60 1600 44.0 32.8 13.00 11.00
GHGD60S41S4
1600 - 2000 24 FC/MC62 1800 55.0 40.0 13.00 11.00
1600 - 2000 24 FC64 1800 56.0 41.5 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.

Related product manuals