036-21121-002 Rev. B (0103)
Unitary Products Group 7
* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
*** This coil is for upflow application only.
H1RA036S25,46
1050
1350
17,21 G1FA036S17,21 1200 33.6 24.9 10.00 - 9.10
21,24 G1FA048S21 1200 36.0 26.6 10.40 - 9.40
17 G1NA036S17J 1200 34.4 25.5 10.00 - 9.20
21 G1NA036S21C 1200 34.4 25.5 10.00 - 9.30
17,21 G1UA036S17,21 1200 33.6 24.9 10.00 - 9.10
21,24 G1UA048S21 1200 36.0 26.6 10.40 - 9.40
17 G2FD036(S,H)17 1200 33.8 25.0 10.00 - 9.20
21 G2FD036(S,H)21 1200 33.8 25.0 10.00 - 9.20
H1RA042S06
1225
1575
17 G1FA048S17 1380 40.0 30.2 10.00 - 9.05
21,24 G1FA048S21 1400 41.0 30.3 10.00 - 9.25
21,24 G1FA060S21,24 1400 42.0 31.0 10.00 - 9.45
- G1HD048 1390 40.5 30.0 10.00 - 9.05
21 G1NA036S21C 1400 40.0 28.3 10.00 - 9.15
21 G1NA048S21D 1400 40.5 28.6 10.00 - 9.15
17 G1UA048S17 1380 40.0 30.2 10.00 - 9.05
21,24 G1UA048S21 1400 41.0 30.3 10.00 - 9.25
21,24 G1UA060S21,24 1400 42.0 31.1 10.00 - 9.45
21 G2FD042(S,H)21 1400 39.5 29.2 10.00 - 9.00
17 G2FD046(S,H)17 1380 40.0 29.6 10.00 - 9.05
21,24 G2FD048(S,H)21,24 1450 41.0 30.3 10.10 - 9.15
24 G2FD060(S,H)24 1450 42.0 31.0 10.10 - 9.50
H1RA042S25,46
1225
1575
21,24 G1FA048S21 1400 41.0 30.3 10.00 - 9.25
21,24 G1FA060S21,24 1400 42.0 31.0 10.00 - 9.45
21 G1NA036S21C 1400 40.0 28.3 10.00 - 9.15
21 G1NA048S21D 1400 40.5 28.6 10.00 - 9.15
21,24 G1UA048S21 1400 41.0 30.3 10.00 - 9.25
21,24 G1UA060S21,24 1400 42.0 31.1 10.00 - 9.45
21 G2FD042(S,H)21 1400 39.5 29.2 10.00 - 9.00
17 G2FD046(S,H)17 1380 40.0 29.6 10.00 - 9.05
21,24 G2FD048(S,H)21,24 1450 41.0 30.3 10.10 - 9.15
H1RA048S06
1400
1800
17 G1FA048S17 1500 44.5 33.5 10.00 - 9.15
21,24 G1FA048S21 1600 45.5 33.7 10.00 - 9.45
21,24 G1FA060S21,24 1600 47.0 34.8 10.40 - 9.70
- G1HD048 1600 45.5 33.7 10.00 - 9.50
- G1HD060 1600 46.5 34.4 10.20 - 9.65
21 G1NA048S21D 1400 46.5 34.4 10.00 - 9.50
17 G1UA048S17 1500 44.5 33.5 10.00 - 9.15
21,24 G1UA048S21 1600 45.5 33.7 10.00 - 9.45
21,24 G1UA060S21,24 1600 47.0 34.8 10.40 - 9.70
17 G2FD046(S,H)17 1500 44.5 32.9 10.00 - 9.15
21,24 G2FD048(S,H)21,24 1600 46.0 34.0 10.10 - 9.50
24 G2FD060(S,H)24 1600 47.0 34.0 10.40 - 9.70
H1RA048S25,46
1400
1800
21,24 G1FA048S21 1600 45.5 33.5 10.00 - 9.45
21 G1NA048S21D 1400 46.5 34.4 10.00 - 9.50
21,24 G1UA048S21 1600 45.5 33.5 10.00 - 9.45
21,24 G2FD048(S,H)21,24 1600 46.0 34.0 10.10 - 9.50
H3RA060S06
1600
2100
21,24 G1FA060S21,24 1800 56.0 40.2 10.50 - 9.35
- G1HD060 2000 55.5 40.0 10.50 - 9.15
21 G1NA048S21D 1500 51.0 34.8 10.00 - 8.90
24 G1NA060S24T 1800 55.0 39.8 10.50 - 9.25
21,24 G1UA060S21,24 1800 56.0 40.2 10.50 - 9.35
24 G2FD060(S,H)24 1800 56.0 40.2 10.50 - 9.35
24 G2FD061H24 2000 57.0 40.9 10.50 - 9.35
H1RA060S25,46
1525
1975
21,24 G1FA060S21,24 1750 58.5 39.8 10.00 - 10.25
24 G1NA060S24T 1750 57.5 39.1 10.00 - 10.00
21,24 G1UA060S21,24 1750 58.5 39.8 10.00 - 10.25
24 G2FD060(S,H)24 1750 58.5 39.8 10.00 - 10.25
H1RA076S25,46 2500-3000 35 G2FD090(S,H)35*** 3200 73.5 52.9 -- -- 10.00
H1RA090S25,46 2500-3000 35 G2FD090(S,H)35*** 4000 90.0 64.8 -- -- 9.35
1. TXV = Use 1TV700 Series Kit.
COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER + TXV
1
EER
TOTAL SENS.