036-21215-003 Rev. B (1202)
12 Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. HAH042S06
INDOOR COIL MODEL NO. G2FD042(S,H)21
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM 1250 1400 1550
ID DB 85 80 75 70 85 80 75 70 85 80 75 70
ID WB 72 67 62 57 72 67 62 57 72 67 62 57
75
T.C. 46.4 43.4 40.4 37.1 47.0 43.9 41.1 37.7 47.5 44.4 41.9 38.3
S.C. 27.7 29.4 30.7 30.8 29.1 30.5 31.9 32.1 30.4 31.7 33.2 33.4
K.W 2.92 2.92 2.89 2.77 3.03 3.02 3.00 2.89 3.16 3.15 3.14 3.03
85
T.C. 44.1 42.3 38.5 34.5 44.8 43.0 39.4 35.1 45.4 43.6 40.3 35.7
S.C. 29.2 29.8 30.3 29.7 30.6 31.4 31.7 31.2 31.9 33.0 33.0 32.6
K.W 3.22 3.20 3.17 3.34 3.32 3.30 3.29 3.49 3.44 3.42 3.43 3.66
95
T.C. 43.4 40.0 36.0 31.9 43.9 40.5 36.6 32.5 44.3 41.1 37.2 33.1
S.C. 28.2 28.4 29.1 28.6 29.9 30.0 30.6 30.2 31.6 31.7 32.1 31.8
K.W 3.62 3.58 3.52 3.44 3.74 3.68 3.64 3.57 3.87 3.81 3.77 3.71
105
T.C. 40.6 37.6 33.4 29.2 41.4 38.1 33.7 29.9 42.1 38.5 34.0 30.6
S.C. 28.6 26.9 27.8 26.9 30.5 28.6 29.5 28.5 32.3 30.3 31.2 30.2
K.W 4.01 3.96 3.87 3.83 4.13 4.07 3.98 3.94 4.26 4.19 4.11 4.07
115
T.C. 37.8 35.3 30.9 26.4 38.9 35.6 30.9 27.2 39.9 36.0 30.9 28.0
S.C. 29.0 25.5 26.6 25.2 31.0 27.2 28.4 26.9 33.0 29.0 30.3 28.5
K.W 4.40 4.34 4.22 4.22 4.52 4.46 4.32 4.31 4.65 4.57 4.45 4.43
125
T.C. 35.0 32.9 28.3 23.7 36.4 33.2 28.0 24.6 37.7 33.4 27.7 25.5
S.C. 29.4 24.0 25.3 23.5 31.6 25.8 27.4 25.2 33.7 27.6 29.4 26.9
K.W 4.79 4.72 4.57 4.61 4.91 4.85 4.66 4.68 5.04 4.95 4.79 4.79
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
N1AHC1606 G2FD042(S,H)21 1.00 1.00 1.00
N1AHC1606 G2FD048(S,H)21 1.02 1.03 0.99
N1VSC16 G2FD042(S,H)21 1.01 1.02 0.94
N1VSC16 G2FD048(S,H)21 1.04 1.04 0.94
G1FA048S17 0.99 0.99 0.99
G1FA048S21 1.00 1.00 0.98
G1FA060S21,24 1.02 1.03 0.99
G1HD048 1.00 1.00 0.98
G1UA048S17 0.99 0.99 0.99
G1UA048S21 1.00 1.00 0.98
G1UA060S21,24 1.02 1.03 0.99
G2FD042(S,H)21 1.00 1.00 1.00
G2FD046(S,H)17 0.99 1.00 0.98
G2FD048(S,H)21,24 1.02 1.03 0.99
G2FD060(S,H)24 1.02 1.03 0.99
Variable Speed
Furnace
Coil
T.C. S.C. KW
P1DUB16V G1FA048S17 1.00 1.01 0.95
P1DUB16V G1UA048S17 1.00 1.01 0.95
P1DUC20V G1FA048S21 1.02 1.03 0.93
P1DUC20V G1UA048S21 1.02 1.03 0.93
P1DUC20V G2FD042(S,H)21 1.01 1.02 0.93
P1XUC16V G1FA048S21 1.01 1.02 0.94
P1XUC16V G1UA048S21 1.01 1.02 0.94
P1XUC16V G2FD042(S,H)21 1.00 1.01 0.94
P1XUC20V G1FA048S21 1.02 1.03 0.94
P1XUC20V G1UA048S21 1.02 1.03 0.94
P1XUC20V G2FD042(S,H)21 1.01 1.02 0.96
P1XUD20V G1FA060S24 1.04 1.06 0.96
P1XUD20V G1UA060S24 1.04 1.06 0.96
P1XUD20V G2FD048(S,H)24 1.04 1.04 0.97