EasyManua.ls Logo

York H4DB024 User Manual

York H4DB024
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
036-21024-006 Rev. D (0403)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
TECHNICAL GUIDE
STELLAR 2000
TM
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER
MODELS: H*DB018 THRU 060
(1 THRU 5 NOMINAL TONS, 1 PH)
H*DB036 THRU 076
(3 THRU 6-1/3 NOMINAL TONS, 3 PH)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
Models 018-048
Model 060
LISTED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Certification applies only
when the complete
system is listed
with ARI.
R
N
E
M
P
I
U
Q
E
T
Y
R
A
T
I
N
U
0
1
2
A
R
I
R
A
D
N
A
T
S
D
I
S
N
O
T
C
E
S
F
O
C
C
I
F
I
T
R
E
N
O
I
T
A
H
T
I
W
C
G
N
I
Y
L
P
M
O
S
A
I
R
A
O
T
D
E
I
F
I
T
R
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
-
G
N
I
N
O
I
T
I
D
N
O
R
I
A
DESCRIPTION
The HDB Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of YORK's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
DURABLE FINISH - Cabinet is made of powder painted
steel over pre-primered steel. The pre-treated galvanized
steel provides a better paint to steel bond, which resists
corrosion and rust creep. Special primer formulas and
automotive quality finish insure less fading when exposed
to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Both quick connect and sweat connect
models are available. Both service valves are firmly affixed
to the unit. The sweat unit contains enough refrigerant for
matching indoor coils and 15 feet of interconnecting pip-
ing. The small base dimension means less space is
required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant
connections, a single panel covering the electrical con-
trols, and the molex plug in the control box connecting the
condenser fan make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York H4DB024 and is the answer not in the manual?

York H4DB024 Specifications

General IconGeneral
BrandYork
ModelH4DB024
CategoryAir Conditioner
LanguageEnglish

Summary

York Heating and Air Conditioning Technical Guide

Product Description

Overview of the HDB Series condensing unit as part of a versatile air conditioning system.

Warranty Information

Details limited parts and compressor warranty for single and three phase units.

Key Features and Benefits

Highlights key features like coil protection, compressor protection, durable finish, and ease of service.

Physical and Electrical Data - 1 Phase

Physical and Electrical Data - 3 Phase

R-22 Charge and Orifice Size - 1 Phase Systems

Orifice Size and Charge Footnotes

Explains unit orifice packing, factory mounting, and system charge calculations.

System Charge Procedures

Details procedures for verifying orifice size, additional charge, and marking the unit nameplate.

R-22 Charge and Orifice Size - 3 Phase Systems

Orifice Size and Charge Footnotes (3 Phase)

Explains unit orifice packing, factory mounting, and system charge calculations for 3-phase.

System Charge Procedures (3 Phase)

Details procedures for verifying orifice size, additional charge, and marking the unit nameplate for 3-phase.

Cooling Capacity with Air Handler Coils

1 Phase 10 SEER AC with N1AH/G2FD

Cooling capacity data for 1-phase 10 SEER units matched with N1AH/G2FD air handlers.

3 Phase 10 SEER AC with N1VS Variable Speed

Cooling capacity data for 3-phase 10 SEER units matched with N1VS variable speed air handlers.

1 Phase 10 SEER AC with N1VS Variable Speed

Cooling capacity data for 1-phase 10 SEER units matched with N1VS variable speed air handlers.

1 Phase 10 SEER AC with F2RP/RC/FP/FC

Cooling capacity data for 1-phase 10 SEER units matched with F2RP/RC/FP/FC fan coil units.

Cooling Capacity with Air Handler Coils (Continued)

1 Phase 10 SEER AC with F2RP/RC/FP/FC (Cont.)

Continued cooling capacity data for 1-phase 10 SEER units with F2RP/RC/FP/FC fan coil units.

3 Phase 10 SEER AC with F2RP/RC/FP/FC

Cooling capacity data for 3-phase 10 SEER units matched with F2RP/RC/FP/FC fan coil units.

3 Phase SEER AC with K2EU

Cooling capacity data for 3-phase SEER units matched with K2EU air handlers.

1 Phase 10 SEER AC with M1HC

Cooling capacity data for 1-phase 10 SEER units matched with M1HC air handlers.

Cooling Capacity with Furnace and Coils

H4DB018 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB018 paired with various furnace and coil combinations.

H4DB024 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB024 paired with various furnace and coil combinations.

H4DB030 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB030 paired with various furnace and coil combinations.

H4DB036S06 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB036S06 paired with various furnace and coil combinations.

Cooling Capacity with Furnace and Coils (Continued)

H4DB036S25,46 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB036S25,46 paired with various furnace and coil combinations.

H5DB042 Cooling Capacity with Furnace Coils

Cooling capacity data for H5DB042 paired with various furnace and coil combinations.

H5DB048 Cooling Capacity with Furnace Coils

Cooling capacity data for H5DB048 paired with various furnace and coil combinations.

H4DB060S06 Cooling Capacity with Furnace Coils

Cooling capacity data for H4DB060S06 paired with various furnace and coil combinations.

Cooling Performance Overview

Cooling Performance Notes

Notes on cooling unit performance, superheat, sub-cooling, and capacity adjustments.

Typical Installation Guidelines

Illustrates typical installation practices and clearances for outdoor units.

Typical Field Wiring - 1 Phase

Wiring Compliance and Components (1 Phase)

Details wiring compliance with codes and identifies key wiring components for 1-phase systems.

Typical Field Wiring - 3 Phase

Wiring Compliance and Components (3 Phase)

Details wiring compliance with codes and identifies key wiring components for 3-phase systems.

Available Accessories

Hard Start Kit Accessory

Provides increased starting torque for low voltage conditions.

Compressor Blanket Accessory

Designed to reduce normal compressor operating sound.

Off Cycle Timer Delay Accessory

Provides a 5-minute off cycle to prevent rapid compressor recycling.

Room Thermostat Options

Offers a selection of compatible thermostats for optimal performance.

Sound Ratings

Lists sound ratings (decibels) for various HDB models.

Cooling Performance Data - H4DB018

Performance Multipliers - Other Indoor Sections

Provides multipliers to adjust performance based on different indoor coil selections.

Cooling Performance Temperature Adjustments

Explains how to adjust sensible capacity based on dry bulb temperature variations.

Cooling Performance Data - H4DB024

Performance Multipliers - Other Indoor Sections (H4DB024)

Provides multipliers to adjust performance for H4DB024 with different indoor coils.

Cooling Performance Temperature Adjustments (H4DB024)

Explains how to adjust sensible capacity for H4DB024 based on temperature variations.

Cooling Performance Data - H4DB030

Performance Multipliers - Other Indoor Sections (H4DB030)

Provides multipliers for H4DB030 to adjust performance with various indoor coils.

Cooling Performance Temperature Adjustments (H4DB030)

Explains sensible capacity adjustments for H4DB030 based on temperature.

Cooling Performance Data - H4DB036

Performance Multipliers - Other Indoor Sections (H4DB036)

Provides multipliers for H4DB036 to adjust performance with various indoor coils.

Cooling Performance Temperature Adjustments (H4DB036)

Explains sensible capacity adjustments for H4DB036 based on temperature.

Cooling Performance Data - H5DB042

Performance Multipliers - Other Indoor Sections (H5DB042)

Provides multipliers for H5DB042 to adjust performance with various indoor coils.

Cooling Performance Temperature Adjustments (H5DB042)

Explains sensible capacity adjustments for H5DB042 based on temperature.

Cooling Performance Data - H5DB048

Performance Multipliers - Other Indoor Sections (H5DB048)

Provides multipliers for H5DB048 to adjust performance with various indoor coils.

Cooling Performance Temperature Adjustments (H5DB048)

Explains sensible capacity adjustments for H5DB048 based on temperature.

Cooling Performance Data - H4DB060

Performance Multipliers - Other Indoor Sections (H4DB060)

Provides multipliers for H4DB060 to adjust performance with various indoor coils.

Cooling Performance Temperature Adjustments (H4DB060)

Explains sensible capacity adjustments for H4DB060 based on temperature.

Cooling Performance Data - H4DB076

Cooling Performance Temperature Adjustments (H4DB076)

Explains sensible capacity adjustments for H4DB076 based on temperature.

Matching Indoor Components

Add-On Coils for Furnace Applications

Displays various add-on coils for furnace applications, including images.

Air Handlers for Non-Furnace Applications

Displays various air handler units for non-furnace applications, including images.

Related product manuals