036-21024-006 Rev. D (0403)
Unitary Products Group 17
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H5DB048
INDOOR COIL MODEL NO. G1FA048S21
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM 1550 1600 1650
ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70
ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57
75
T.C. 53.0 49.0 45.0 41.2 53.2 49.2 45.2 41.4 53.4 49.3 45.3 41.5
S.C. 34.5 34.8 35.3 35.6 35.0 35.2 35.8 36.0 35.4 35.6 36.3 36.5
K.W 4.06 3.98 3.91 3.85 4.08 4.00 3.93 3.86 4.10 4.02 3.95 3.88
85
T.C. 52.6 48.5 44.5 40.9 52.7 48.7 44.6 41.0 52.9 48.9 44.8 41.2
S.C. 34.9 35.1 35.8 36.1 35.4 35.7 36.3 36.6 36.0 36.2 36.7 37.0
K.W 4.44 4.35 4.26 4.19 4.45 4.36 4.28 4.21 4.47 4.38 4.30 4.23
95
T.C. 51.3 47.3 43.4 39.7 51.5 47.5 43.4 39.9 51.6 47.6 43.6 40.0
S.C. 34.9 35.1 35.8 35.8 35.4 35.6 36.1 36.3 35.9 36.1 36.6 36.8
K.W 4.72 4.62 4.53 4.45 4.73 4.64 4.55 4.47 4.76 4.66 4.57 4.49
105
T.C. 49.6 45.7 41.7 38.3 49.7 45.8 41.9 38.4 49.9 46.0 42.1 38.6
S.C. 34.4 34.7 35.0 35.2 34.9 35.2 35.7 35.7 35.5 35.7 36.4 36.3
K.W 5.00 4.90 4.81 4.71 5.01 4.91 4.81 4.73 5.03 4.94 4.84 4.76
115
T.C. 47.6 43.9 40.1 36.7 47.8 44.0 40.3 36.8 47.9 44.1 40.4 37.0
S.C. 33.6 33.8 34.4 34.4 34.3 34.4 35.1 34.9 34.7 34.9 35.4 35.5
K.W 5.29 5.18 5.08 4.98 5.30 5.20 5.09 5.00 5.33 5.22 5.12 5.02
125
T.C. 45.6 42.1 38.5 35.1 45.9 42.2 38.7 35.2 45.9 42.2 38.7 35.4
S.C. 32.8 32.9 33.8 33.6 33.7 33.6 34.5 34.1 33.9 34.1 34.4 34.7
K.W 5.58 5.46 5.35 5.25 5.59 5.49 5.37 5.27 5.63 5.50 5.40 5.28
NOTE:
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
N1AHC16 G2FD048(S,H)21 1.02 1.02 1.02
N1AHC16 G2FD048(S,H)24 1.02 1.02 1.00
N1AHD20 G2FD060(S,H)24 1.03 1.03 1.01
N1VSC16 G2FD048(S,H)21 1.03 1.03 0.98
N1VSD20 G2FD048(S,H)24 1.04 1.04 0.97
N1VSD20 G2FD060(S,H)24 1.03 1.03 1.00
F2FP048 1.00 0.99 1.00
F2FP060 1.01 1.00 1.02
Coil
T.C. S.C. KW
G1UA048S21 1.00 1.00 1.00
G2FD060(S,H)24 1.03 1.03 1.01
G1FA060S21,24 1.03 1.03 1.01
G2FD048(S,H)21,24 1.02 1.02 1.02
G1FD046S17 1.00 1.00 1.09
G1HD048 1.01 1.01 1.06
G1HD060 1.02 1.02 1.00
G1NA048S21D 0.98 0.98 1.04
G1UA060S21,24 1.03 1.03 1.01