Johnson Controls Unitary Products 1183746-UIM-B-0215
®
SINGLE PACKAGE
AIR CONDITIONER/GAS HEAT
MODELS: PCG4 Series
(2-5 Ton)
INSTALLATION MANUAL
LIST OF SECTIONS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AIRFLOW PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
LIST OF FIGURES
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unit 4 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bottom Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Rear Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Field Control Wiring Diagram For Gas Heat - AC Models . . . 7
Typical Field Power Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 7
Flue Vent Outlet Air Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Connection Wiring Diagram - 2 to 3 Ton Models . . . . . . . . . . . . . . . 19
Ladder Wiring Diagram - 2 to 3 Ton Models . . . . . . . . . . . . . . . . . . . 20
Connection Wiring Diagram - 3.5 to 5 Ton Models . . . . . . . . . . . . . .21
Ladder Wiring Diagram - 3.5 to 5 Ton Models . . . . . . . . . . . . . . . . . 22
R-410A Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
LIST OF TABLES
Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Natural Gas Pipe Sizing Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Propane (LP) Gas Pipe Sizing Chart . . . . . . . . . . . . . . . . . . . . . . . . . 9
Natural Gas Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Propane (LP) Gas Application Data . . . . . . . . . . . . . . . . . . . . . . . . . 10
Airflow - Side Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Airflow - Bottom Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Additional Static Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Ignition Control Board Flash Codes . . . . . . . . . . . . . . . . . . . . . . . . .16
Gas Rate Cubic Feet Per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SECTION I: GENERAL INFORMATION
These are electric cooling/gas heating units designed for outdoor instal-
lation. Only gas piping, electric power and duct connections are
required at the point of installation.
The gas-fired heaters have spark ignition.
The refrigerant system is fully charged with R-410A Refrigerant, and is
tested and factory sealed.
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury.
It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Failure to carefully read and
follow all instructions in this manual can result in furnace mal-
function, death, personal injury and/or property damage. Only a
qualified contractor, installer or service agency should install this
product.
CAUTION
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
!
!
Question and Answer IconNeed help?

Do you have a question about the York PCG4 Series and is the answer not in the manual?

York PCG4 Series Specifications

General IconGeneral
BrandYork
ModelPCG4 Series
CategoryAir Conditioner
LanguageEnglish

Summary

GENERAL INFORMATION

SAFETY

Signal Word Definitions

Explains the meaning of DANGER, WARNING, and CAUTION signal words for hazard identification.

MODEL NUMBER NOMENCLATURE

LIMITATIONS

US Installation Codes and Requirements

Lists national and local codes required for installation in the USA.

Canadian Installation Codes and Requirements

Lists national and local codes required for installation in Canada.

LOCATION

CLEARANCES

RIGGING AND HANDLING

DUCTWORK

FILTERS

CONDENSATE DRAIN

SERVICE ACCESS

THERMOSTAT

POWER AND CONTROL WIRING

COMPRESSORS

GAS HEAT

GAS PIPING

Details requirements for sizing and installing gas piping, including codes and materials.

GAS CONNECTION

Describes routing the gas supply line through the unit and sealing the grommet.

FLUE VENT AND AIR INTAKE HOOD

AIRFLOW PERFORMANCE

OPERATION

HEATING SEQUENCE OF OPERATION

Details the steps the control board takes to initiate and maintain heating operation.

SAFETY CONTROLS

Lists and describes safety controls like limit switches, pressure switches, and flame sensors.

CIRCULATING FAN

Explains how the indoor blower operates during different modes (heat, cool, fan only).

COOLING SEQUENCE OF OPERATIONS

Details how the unit operates during cooling cycles based on thermostat input.

MAIN BURNER OPERATION

START-UP

PRESTART CHECK LIST

Lists checks to perform before initial unit start-up to ensure proper installation.

OPERATING INSTRUCTIONS

Provides step-by-step instructions for safe and correct initial unit operation.

TO TURN OFF GAS TO UNIT

Instructions on how to safely shut off the gas supply to the unit.

POST START CHECK LIST

Lists checks to perform after initial start-up to verify correct operation.

MANIFOLD GAS PRESSURE ADJUSTMENT

Details how to adjust the manifold gas pressure for optimal performance.

ADJUSTMENT OF TEMPERATURE RISE

Explains how to measure and ensure correct temperature rise for efficient heating.

DIRECT DRIVE BLOWER

CHECKING GAS HEAT INPUT

TYPICAL WIRING DIAGRAMS

CONNECTION WIRING DIAGRAM - 2 TO 3 TON MODELS

Provides the connection wiring diagram for 2 to 3 ton models.

LADDER WIRING DIAGRAM - 2 TO 3 TON MODELS

CONNECTION WIRING DIAGRAM - 3.5 TO 5 TON MODELS

LADDER WIRING DIAGRAM - 3.5 TO 5 TON MODELS

R-410A QUICK REFERENCE GUIDE

START UP SHEET

GENERAL INFORMATION

Basic information about the unit's type and installation environment.

UNIT LOCATION AND CONNECTIONS

Details checks for unit level, installation surface, and duct connections.

FILTERS

Section to record filter installation details and quantities.

ADDITIONAL KITS & ACCESSORIES INSTALLED

Checklist for installed optional kits and accessories.

ELECTRICAL CONNECTIONS & INSPECTION

Inspection points for electrical connections, voltage, and grounding.

AIR FLOW SETUP / COOLING

Settings and measurements for airflow and temperature during cooling operation.

BLOWER TYPE & SET-UP

Details blower type and speed settings for optimal performance.

REFRIGERANT CHARGE AND METERING DEVICE

GAS HEAT

CLEAN UP JOB SITE

UNIT OPERATION AND CYCLE TEST

OWNER EDUCATION