Johnson Controls Unitary Products 5126744-UIM-D-1015
®
®
SINGLE PACKAGE
AIR CONDITIONER/ELECTRIC
MODELS: PCE4 Series
(2-5 Ton)
INSTALLATION MANUAL
LIST OF SECTIONS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AIRFLOW PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
LIST OF FIGURES
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unit 4 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bottom Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Rear Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Field Control Wiring Diagram For Air Conditioner Models . . . 7
Typical Field Power Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 7
Single Point Wiring Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Measuring External Static Pressure . . . . . . . . . . . . . . . . . . . . . . . . .17
Connection Wiring Diagram - 2 to 3 Ton Models . . . . . . . . . . . . . . .18
Ladder Wiring Diagram - 2 to 3 Ton Models . . . . . . . . . . . . . . . . . . .19
Connection Wiring Diagram - 3.5 to 5 Ton Models . . . . . . . . . . . . . .20
Ladder Wiring Diagram - 3.5 to 5 Ton Models . . . . . . . . . . . . . . . . .21
R-410A Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
LIST OF TABLES
Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Clearances, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Data - 208/230-1-60 - Single Source Power
Single Point Connection Kit Required . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Data for 208-1-60 Multi Source Power . . . . . . . . . . . . . . . . 9
Electrical Data for 230-1-60 Multi Source Power . . . . . . . . . . . . . . . 10
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Airflow - Side Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Airflow - Bottom Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Electric Heat Minimum Supply Air . . . . . . . . . . . . . . . . . . . . . . . . . .15
Electric Heat Multipliers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Additional Static Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Thermostat Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SECTION I: GENERAL INFORMATION
PCE units are factory assembled air conditioners designed for outdoor
installation on a roof top or a slab. Field-installed electric heater acces-
sories are available to provide electric heat.
The units are completely assembled on rigid, removable base rails. All
piping, refrigerant charge, and electrical wiring is factory installed and
tested. The units require only electric power and duct connections at
the point of installation.
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Failure to carefully read and
follow all instructions in this manual can result in furnace mal-
function, death, personal injury and/or property damage. Only a
qualified contractor, installer or service agency should install this
product.
CAUTION
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
!
!
Question and Answer IconNeed help?

Do you have a question about the York PCE4 Series and is the answer not in the manual?

York PCE4 Series Specifications

General IconGeneral
TypeAir Conditioner
RefrigerantR-410A
Cooling Capacity9, 000 - 36, 000 BTU/h
Energy Efficiency Ratio (EER)Up to 12.5
Indoor Unit Dimensions (HxWxD)Varies by model
Outdoor Unit Dimensions (HxWxD)Varies by model
Indoor Unit WeightVaries by model
Outdoor Unit WeightVaries by model
SeriesPCE4 Series
Power Supply208/230V, 1-phase, 60Hz
Noise Level (Indoor Unit)As low as 56 dB
Noise Level (Outdoor Unit)As low as 72 dB

Summary

General Information and Installation

Safety Precautions

Safety alerts and signal words (DANGER, WARNING, CAUTION) for potential hazards.

Model Number Nomenclature

Explanation of the model number's components and their meaning.

Installation Requirements

Installation limitations, location, clearances, rigging, and ductwork guidelines.

Filters and Service Access

Filter maintenance, condensate drain, and access to serviceable components.

Electrical and Wiring Information

Power and Control Wiring

Field wiring, electrical codes, and typical control/power wiring diagrams.

Electrical Data Tables

Specifications for 208/230V single and multi-source power configurations.

Single-Point Wiring Kits

Details on single-point kits and their compatibility with unit models and heater kits.

Wiring Diagrams

Connection and ladder diagrams for reciprocating and scroll compressors.

Unit Specifications and Operation

Physical and Airflow Data

Unit dimensions, weights, compressor details, and airflow performance tables.

Operation Sequences

Procedures for cooling, heating, and electric heat limit switch operation.

Thermostat Signals

Table mapping thermostat signals (G, Y, W) to unit functions.

Startup, Maintenance, and Troubleshooting

Startup Procedures

Step-by-step guide for initial unit startup and checks.

External Static Pressure Setup

Method for measuring and calculating total system static pressure.

Normal Maintenance

Routine maintenance tasks for filters, coils, and motors.

Troubleshooting

Guidance for diagnosing and resolving potential unit issues.

Specialized Guides and Forms

R-410A Quick Reference Guide

Essential precautions and requirements for servicing systems with R-410A refrigerant.

Start Up Sheet

Checklist for unit startup, electrical checks, airflow, refrigerant, and owner education.