Johnson Controls Unitary Products 5285473-UIM-E-1217
®
®
SINGLE PACKAGE
AIR CONDITIONER / GAS HEAT
MODELS: PCG6 SERIES
3 THRU 5 TONS – 208/230V - 3 PHASE
INSTALLATION MANUAL
LIST OF SECTIONS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
AIRFLOW PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
LIST OF FIGURES
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Center of Gravity Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bottom Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Rear Duct Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Field Control Wiring Diagram For Gas Heat - AC Models . . . 7
Typical Field Power Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 7
Flue Vent Outlet Air Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Gas Valve 19
Reading Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Measuring External Static Pressure . . . . . . . . . . . . . . . . . . . . . . . . .21
Connection Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Ladder Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
R-410A Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
LIST OF TABLES
Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Natural Gas Pipe Sizing Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Propane (LP) Gas Pipe Sizing Chart . . . . . . . . . . . . . . . . . . . . . . . . 10
Natural Gas Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Propane,4 (LP) Gas Application Data . . . . . . . . . . . . . . . . . . . . . . . .11
Airflow Performance - Side Duct Application . . . . . . . . . . . . . . . . . .11
Additional Static Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Ignition Control Board Flash Codes . . . . . . . . . . . . . . . . . . . . . . . . .17
Delay Profile Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Gas Rate Cubic Feet Per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
SECTION I: GENERAL INFORMATION
These are electric cooling/gas heating units designed for outdoor instal-
lation. Only gas piping, electric power and duct connections are
required for installation.
The gas-fired heaters have spark ignition.
The refrigerant system is fully charged with R-410A Refrigerant. The
system is tested and factory sealed.
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
WARNING
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Failure to carefully read and
follow all instructions in this manual can result in furnace mal-
function, death, personal injury and/or property damage. Only a
qualified contractor, installer or service agency should install this
product.
!

Other manuals for York PCG6B48

Question and Answer IconNeed help?

Do you have a question about the York PCG6B48 and is the answer not in the manual?

York PCG6B48 Specifications

General IconGeneral
BrandYork
ModelPCG6B48
CategoryAir Conditioner
LanguageEnglish

Summary

General Information

Safety

Safety alert symbols and signal words DANGER, WARNING, or CAUTION.

Installation Safety

Installation Precautions

Essential safety guidelines and precautions before starting unit installation.

Fire and Explosion Hazards

Critical warnings about fire and explosion hazards during installation.

Location Guidelines

Combustion Air Contamination Warning

Warnings about contaminated combustion air and its effects on equipment and injury.

Clearances

Obstruction Clearance Warning

Warning to avoid obstructing condenser air discharge, combustion air inlet, or vent outlets.

Power and Control Wiring

Gas Heat and Piping

Gas Connection

Gas Leak Testing Warning

Critical warning about fire/explosion hazards and never testing gas leaks with an open flame.

Heating Sequence of Operation

Pressure Switch and Pre-Purge

Process of proving pressure switch operation and pre-purge sequence.

Ignition Trial and Flame Stabilization

Sequence for igniting gas burners and flame stabilization.

Heating Operation Details

High Temperature and Rollout Safety

Operation and lockout conditions for limit switches and rollout switches.

Fault Conditions and Lockouts

Handling of flame faults, gas valve faults, and general lockouts.

Cooling Sequence of Operations

Cooling Stages and Fan Delay

Sequence for cooling stages and fan off-delay timing.

Delay Profiles and Safety Switches

High Pressure and Low Charge Switches

Description and function of high pressure and low charge safety switches.

Start-Up Procedures

Gas Pressure and Input Rate Adjustment

Measuring Gas Pressures

Procedure for measuring inlet and manifold gas pressures using a manometer.

Gas Pressure and Input Rate Warnings

Important notes on gas line pressure requirements and factory calibration.

Manifold Pressure Adjustment

Procedure for adjusting manifold gas pressure for high and low fire.

Gas Heat Input Check

Natural Gas Input Measurement

Procedure for checking natural gas heat input using a gas meter.

Temperature Rise Adjustment

Temperature Rise Measurement Warning

Danger warnings about exceeding maximum supply air temperature during operation.

Adjusting Temperature Rise

Procedure for measuring and adjusting furnace temperature rise by changing blower speed.

Troubleshooting

Electrical Troubleshooting Warning

Warning about opening electrical control boxes with power connected.

Typical Wiring Diagrams

Wiring Diagrams

DSI Fault Codes

List of fault codes for the Direct Spark Ignition control board and their descriptions.

R-410 A Quick Reference Guide

R-410 A Installation Requirements

Specific requirements for installing systems using R-410A refrigerant.

Start Up Sheet

Refrigerant Charge and Metering Device

Gas Heat and Operation

Unit Operation and Cycle Test