Do you have a question about the York PS9A12N040UP11 and is the answer not in the manual?
Details Category IV, highly efficient, compact, condensing furnaces for residential and commercial use.
Outlines lifetime limited warranty on heat exchangers and 5-year limited parts warranty.
Lists compact design, easy installation, self-diagnostics, electronic ignition, and safety features.
Provides cabinet dimensions (A, B, C, D) for various furnace models.
Details maximum elbows and vent lengths for different BTUH inputs and pipe sizes.
Lists input/output, blower size, motor specs, and max over-current protection.
Details outlet air temp, airflow, AFUE, and operating weight for each model.
Provides airflow (CFM) data for various static pressures with bottom/side return.
Provides airflow (CFM) data for various static pressures with two side returns.
Lists typical pressure drop values (In w.c.) for disposable, washable, and pleated filters.
Steps and examples for calculating system airflow with filter pressure drop.
Kit to convert natural gas units to propane operation.
Concentric and sidewall kits for various venting configurations.
Kit for neutralising condensate discharge.
External bottom and side return filter racks for filter installation.
Accessory kits for converting units for high altitude operation.
Selection of compatible thermostats for optimal performance.
Details Category IV, highly efficient, compact, condensing furnaces for residential and commercial use.
Outlines lifetime limited warranty on heat exchangers and 5-year limited parts warranty.
Lists compact design, easy installation, self-diagnostics, electronic ignition, and safety features.
Provides cabinet dimensions (A, B, C, D) for various furnace models.
Details maximum elbows and vent lengths for different BTUH inputs and pipe sizes.
Lists input/output, blower size, motor specs, and max over-current protection.
Details outlet air temp, airflow, AFUE, and operating weight for each model.
Provides airflow (CFM) data for various static pressures with bottom/side return.
Provides airflow (CFM) data for various static pressures with two side returns.
Lists typical pressure drop values (In w.c.) for disposable, washable, and pleated filters.
Steps and examples for calculating system airflow with filter pressure drop.
Kit to convert natural gas units to propane operation.
Concentric and sidewall kits for various venting configurations.
Kit for neutralising condensate discharge.
External bottom and side return filter racks for filter installation.
Accessory kits for converting units for high altitude operation.
Selection of compatible thermostats for optimal performance.
Loading...