5752574-UTG-C-1020
10 Johnson Controls Ducted Systems
– = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
Furnaces that are listed individually in the above table, such as the RGF1L*P, RGF19*P, and RGF1L*E, use Coil Only Ratings.
RAC13L36B24S CF/CM/CU36C 21.0 1000–1400 1200 35.4 28.0 13.00 11.00
RAC13L36B24S CF/CM/CU42C 21.0 1000–1400 1200 35.8 27.6 13.00 11.00
RAC13L36B24S CF/CM/CU48C 21.0 1000–1400 1200 35.8 27.8 13.00 11.25
RAC13L36B24S CF/CM/CU48D 24.5 1000–1400 1200 35.8 27.8 13.00 11.25
RAC13L36B24S CF/CM36D 24.5 1000–1400 1200 35.4 28.0 13.00 11.00
RAC13L36B24S CF/CM42D 24.5 1000–1400 1200 35.8 27.6 13.00 11.00
RAC13L36B24S CF42B 17.5 1000–1400 1200 35.8 27.6 13.00 11.00
RAC13L42B24S CF/CM/CU42C 21.0 1200–1600 1400 40.5 29.0 13.00 11.00
RAC13L42B24S CF/CM/CU42C 21.0 1200–1600 1400 40.5 29.0 13.00 11.00
RAC13L42B24S CF/CM/CU48C 21.0 1200–1600 1400 41.0 32.1 13.00 11.25
RAC13L42B24S CF/CM/CU48D 24.5 1200–1600 1400 41.0 32.1 13.00 11.25
RAC13L42B24S CF/CM/CU60C 21.0 1200–1600 1400 40.5 31.6 13.00 11.25
RAC13L42B24S CF/CM42D 24.5 1200–1600 1400 41.0 32.4 13.00 11.25
RAC13L42B24S CF/CM64D 24.5 1200–1600 1400 42.0 33.1 13.00 11.50
RAC13L48B23S CF/CM/CU48C 21.0 1400–1800 1600 46.0 33.5 13.00 11.00
RAC13L48B23S CF/CM/CU48D 24.5 1400–1800 1600 46.0 33.5 13.00 11.00
RAC13L48B23S CF/CM/CU60C 21.0 1400–1800 1600 48.0 36.0 13.00 11.25
RAC13L48B23S CF/CM/CU60D 24.5 1400–1800 1600 48.0 36.0 13.00 11.25
RAC13L48B23S CF/CM64D 24.5 1400–1800 1600 48.0 36.0 13.00 11.25
RAC13L60B23S CF/CM/CU60C 21.0 1520–1920 1725 55.0 41.0 13.00 11.00
RAC13L60B23S CF/CM/CU60D 24.5 1520–1920 1725 55.5 38.0 13.00 11.00
RAC13L60B23S CF/CM/CU60D 24.5 1520–1920 1725 55.5 38.0 13.00 11.00
RAC13L60B23S CF/CM64D 24.5 1520–1920 1725 56.5 42.5 13.00 11.00
For rated condition information, see the COOLING CAPACITY - With Air Handler Coils table footnotes.
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
COOLING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings) (Continued)
UNIT MODEL
COIL
CFM RANGE
(MINIMUM–
MAXIMUM)
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.