5591306-YTG-F-0220
6 Johnson Controls Ducted Systems
3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
THE42B(3,4)3S AVC42CX21 21.0 – 1150 40.0 29.2 15.00 12.25 40.0 25.4 8.20 7.25 3.34 2.62
THE42B(3,4)3S AVC48CX21 21.0 – 1200 40.5 30.0 15.00 12.25 40.0 25.4 8.20 7.25 3.38 2.64
THE42B(3,4)3S AVC48DX21 24.5 – 1150 40.5 29.6 15.50 12.25 40.0 25.2 8.20 7.25 3.38 2.66
THE42B(3,4)3S ME14DN21 24.5 CF/CM48D 1200 40.5 30.0 15.25 12.25 40.0 25.2 8.20 7.25 3.40 2.66
THE42B(3,4)3S ME16CN21 21.0 CF/CM48C 1325 40.5 31.6 15.00 12.20 40.0 25.4 8.20 7.25 3.42 2.64
THE42B(3,4)3S ME20DN21 24.5 CF/CM48D 1275 41.0 31.2 15.50 12.50 39.5 25.2 8.50 7.50 3.46 2.66
THE42B(3,4)3S MVC14DN21 24.5 CF/CM48D 1175 40.5 29.8 15.50 12.50 40.0 25.0 8.20 7.25 3.40 2.68
THE42B(3,4)3S MVC16CN21 21.0 CF/CM48C 1150 40.5 29.6 15.25 12.25 40.0 25.2 8.20 7.25 3.36 2.66
THE42B(3,4)3S MVC20DN21 24.5 CF/CM48D 1175 40.5 29.8 15.50 12.50 40.0 25.0 8.20 7.25 3.40 2.68
THE48B(3,4)1S AE48CX21 21.0 – 1,400 46.0 31.8 14.25 12.00 47.5 31.4 9.00 7.82 3.58 2.64
THE48B(3,4)1S AE48DX21 24.5 – 1,400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 7.82 3.62 2.66
THE48B(3,4)1S AE60CX21 21.0 – 1,520 47.0 33.3 15.00 12.50 47.5 31.4 9.00 7.82 3.66 2.66
THE48B(3,4)1S AVC48CX21 21.0 – 1,375 46.0 31.6 14.25 12.00 47.5 31.4 9.00 7.82 3.56 2.62
THE48B(3,4)1S AVC48DX21 24.5 – 1,400 46.5 31.6 14.75 12.25 47.5 31.2 9.00 7.82 3.60 2.66
THE48B(3,4)1S AVC60CX21 21.0 – 1,350 46.5 31.6 15.00 12.50 47.5 31.2 9.00 7.82 3.56 2.62
THE48B(3,4)1S ME14DN21 24.5 CF/CM48D 1,400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 7.82 3.60 2.66
THE48B(3,4)1S ME14DN21 24.5 CF/CM60D 1,400 46.5 32.0 14.25 12.00 48.0 31.4 9.00 7.82 3.54 2.60
THE48B(3,4)1S ME16CN21 21.0 CF/CM48C 1,400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 7.82 3.58 2.64
THE48B(3,4)1S ME16CN21 21.0 CF/CM60C 1,400 47.0 32.2 14.50 12.25 47.5 31.2 9.00 7.82 3.58 2.62
THE48B(3,4)1S ME20DN21 24.5 CF/CM48D 1,400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 7.82 3.60 2.66
THE48B(3,4)1S ME20DN21 24.5 CF/CM60D 1,400 47.0 32.2 14.75 12.25 47.5 31.2 9.00 7.82 3.58 2.64
THE60B(3,4)1S AE60DX21 24.5 – 1640 55.5 38.5 14.25 12.00 57.0 37.8 9.00 7.82 3.88 2.82
THE60B(3,4)1S AVC60DX21 24.5 – 1550 55.5 38.5 14.25 12.00 57.0 37.8 9.00 7.82 3.88 2.82
THE60B(3,4)1S ME20DN21 24.5 CF/CM64D 1600 55.0 38.0 14.25 12.00 57.0 37.6 9.25 8.04 3.88 2.82
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
UNIT
MODEL
AIR HANDLER
COIL
MODEL
3
RATED
CFM
COOLING
1
HEATING
2
MODEL WIDTH
NET MBH
SEER EER
NET MBH
HSPF
Region IV
HSPF
Region V
COP
TOTAL SENS. 47°F OD 17°F OD 47°F OD 17°F OD