EasyManua.ls Logo

York THE36B32S User Manual

York THE36B32S
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL GUIDE
LX
SERIES
SPLIT SYSTEM
HEAT PUMPS
14 SEER – R-410A – 3 PHASE
2.5 THRU 5 NOMINAL TONS
MODELS: THE18 THRU 60
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.simplygettingthejobdone.com and
www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Standard 1-Year limited parts warranty.
Standard 5-Years limited compressor warranty.
*Does not apply to R-22 models or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
FOR INSTALLATION IN ALL US REGIONS AND CANADA
Installation Allowed
®
5591306-YTG-F-0220
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The THE model outdoor units are optimized for the 14 SEER /
8.2 HSPF Minimum Efficiency in all US Regions, and are spe-
cifically designed to be matched with York indoor coils, fur-
naces, and air handlers to provide a complete system solution.
FEATURES
Easier Installation - Independent panels provide quick
access for unit setup. Installation time is reduced by easy
power and control wiring access. The factory installed filter-
drier and factory charge for a 15-Ft lineset means less time
spent brazing and charging the system. The small base
dimension and reduced unit clearances make for easier ret-
rofits.
Accessible Information - QR code on unit provides quick
access to technical documents and warranty information.
Durable Finish - The coated steel wire fan guard, coated
external fasteners, and pre-treated G90-equivalent galva-
nized steel chassis components resist corrosion and rust
creep. Champagne colored powdercoat paint further protects
external panels.
Rugged Coil Protection - Coils are protected from mechan-
ical damage by a proven stamped steel coil guard design.
Quality Coils - Enhanced aluminum fins are mechanically
bonded to copper tubing.
Protected Compressor - Compressors are protected inter-
nally by a high pressure relief valve and a temperature sen-
sor, and externally by the system high and low pressure
switches. The liquid line filter-drier is factory installed to pro-
tect the compressor against moisture and debris.
Reliable Operation - Ball bearing fan motors provide supe-
rior performance in extreme temperatures. Factory installed
accumulator ensures proper functioning across a wide range
of conditions.
Environmentally Friendly - CFC-free R-410A refrigerant
delivers environmentally friendly performance with zero
ozone depletion.
Top Discharge - Warm air is blown up, away from the struc-
ture and any landscaping and allows compact location on
multi-unit applications.
Low Operating Sound Levels - Developed using CFD and
FEA tools, the sturdy cabinet and top design provides sound
performance of 76 dBA or lower. Compatible accessories for
further sound reduction are also available.
Better Service Access - Diagonal base valves with open
access for low-loss fittings, single panel access to the electri-
cal controls, full corner access, and removable fan guard
allow easy access for unit maintenance.
Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.
Question and Answer IconNeed help?

Do you have a question about the York THE36B32S and is the answer not in the manual?

York THE36B32S Specifications

General IconGeneral
Model NumberTHE36B32S
CategoryHeat Pump
Cooling Capacity (BTU/h)36000
Heating Capacity (BTU/h)36000
SEER Rating16
HSPF Rating9.0
Refrigerant TypeR-410A
Voltage (V)208/230
Phase1
Sound Level (dBA)74

Summary

FEATURES

Easier Installation

Provides quick access for unit setup, reduced time for brazing and charging.

Better Service Access

Diagonal base valves and single panel access for easy unit maintenance.

NOMENCLATURE

PHYSICAL AND ELECTRICAL DATA

SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS

CHARGING PROCEDURES

Step-by-step guide for proper refrigerant charging of the system.

MECHANICAL SPECIFICATIONS

UNIT WARRANTIES

Details on compressor and parts warranty coverage.

TYPICAL INSTALLATION

PERFORMANCE DATA - 2.5 ΤΟΝ

HEATING PERFORMANCE DATA

Related product manuals