5591306-YTG-F-0220
Johnson Controls Ducted Systems 7
— = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
SYSTEM CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING HEATING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
NET MBH
HSPF
Region IV
HSPF
Region V
COP
TOTAL SENS. 47°F OD 17°F OD 47°F OD 17°F OD
THE30B(3,4)1S CF/CM/CU36B 17.5 800 - 1200 1000 28.8 21.2 14.00 12.00 29.6 20.0 8.55 7.43 3.74 2.62
THE30B(3,4)1S CF/CM/CU36C 21.0 800 - 1200 1000 28.8 21.2 14.00 12.00 29.6 20.0 8.55 7.43 3.74 2.62
THE30B(3,4)1S CF/CM/CU36D 24.5 800 - 1200 1000 28.8 21.2 14.00 12.00 29.6 20.0 8.55 7.43 3.74 2.62
THE30B(3,4)1S CF/CM/CU42C 21.0 800 - 1200 1000 29.2 21.6 14.00 12.00 29.2 19.6 8.55 7.43 3.74 2.60
THE30B(3,4)1S CF/CM/CU42D 24.5 800 - 1200 1000 29.2 21.6 14.00 12.00 29.2 19.6 8.55 7.43 3.74 2.60
THE30B(3,4)1S CF/CM36A 14.5 800 - 1200 900 28.4 20.2 14.00 12.00 29.4 20.0 8.55 7.43 3.68 2.62
THE36B(3,4)2S CF/CM/CU48C 21.0 1000 - 1400 1200 36.0 27.6 14.25 12.20 35.8 23.4 8.50 7.75 3.54 2.46
THE36B(3,4)2S CF/CM/CU48D 24.5 1000 - 1400 1200 36.0 27.6 14.25 12.20 35.8 23.4 8.50 7.75 3.54 2.46
THE42B(3,4)3S CF/CM/CU48C 21.0 1200 - 1600 1400 40.5 32.0 14.00 11.25 40.5 26.0 8.20 7.30 3.32 2.54
THE42B(3,4)3S CF/CM/CU48D 24.5 1200 - 1600 1400 40.5 32.0 14.00 11.25 40.5 26.0 8.20 7.30 3.32 2.54
THE48B(3,4)1S CF/CM/CU60C 21.0 1400 - 1600 1,600 47.0 33.8 14.00 11.75 47.5 32.0 8.20 7.13 3.54 2.50
THE48B(3,4)1S CF/CM/CU60D 24.5 1400 - 1600 1,600 47.0 33.8 14.00 11.75 47.5 32.0 8.20 7.13 3.54 2.50
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60 second time delay.