835959-UIM-D-0814
R-410A OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS: 14.5 SEER - YHJF60/THJF60
5 TONS – 1 PHASE
INSTALLATION MANUAL
®
LIST OF SECTIONS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INDOOR EXPANSION DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SYSTEM START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
LIST OF FIGURES
Typical Installation with Required Clearances . . . . . . . . . . . . . . . . . . .2
Tubing Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Outdoor Unit Control Box - 14.5 SEER 60 Only . . . . . . . . . . . . . . . . . .7
Thermostat Wiring – Two-Stage Heat Pump -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Thermostat Wiring – Two-Stage Heat Pump -
Variable Speed Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
CFM Selection Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Heat Pump Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Wiring Diagram - Single Phase - 14.5 SEER - 5 Ton . . . . . . . . . . . . 12
LIST OF TABLES
Maximum / Minimum Operating Limit Conditions . . . . . . . . . . . . . . . . .2 R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for the smallest rated indoor coil plus 15 feet of field
supplied lines.
Matching indoor coils require a matching thermostatic expansion valve
(TXV) - refer to the Tabular Data Sheet or Technical Guide. The refrig-
erant charge may need to be changed for some indoor-outdoor unit
combinations, elevation differences, or total line lengths. Refer to Appli-
cation Data covering “General Piping Recommendations and Refriger-
ant Line Length” (Part Number 247077).
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury
. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service, or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer, or service agency.
This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.
R-410A systems operate at higher pressures than R-22 systems. Do
not use R-22 service equipment or components on R-410A equip-
ment. Service equipment
Must Be Rated for R-410A.
Question and Answer IconNeed help?

Do you have a question about the York THJF60 and is the answer not in the manual?

York THJF60 Specifications

General IconGeneral
BrandYork
ModelTHJF60
CategoryHeat Pump
LanguageEnglish

Summary

SECTION I: GENERAL

SECTION II: SAFETY

SECTION III: UNIT INSTALLATION

LOCATION

Details on selecting a suitable location for outdoor and indoor units.

ADD-ON REPLACEMENT/RETROFIT

Steps for replacing R-22 systems with R-410A equipment.

GROUND INSTALLATION

Guidance for installing the outdoor unit at ground level.

ROOF INSTALLATION

Considerations for mounting units on a roof structure.

WALL MOUNT INSTALLATION

Requirements for securing units to walls.

UNIT PLACEMENT

Notes on positioning the unit and inspecting for damage.

LIQUID LINE FILTER-DRIER

Details on the filter-drier and its importance.

PIPING CONNECTIONS AND PRECAUTIONS

Instructions and precautions for connecting refrigerant lines.

PRECAUTIONS DURING BRAZING OF LINES

Guidelines for brazing refrigerant lines to prevent damage.

PRECAUTIONS DURING BRAZING SERVICE VALVE

Steps to protect service valves during brazing.

THERMOSTATIC EXPANSION VALVE (TXV) INSTALLATION

Detailed steps for installing the TXV kit and its components.

SECTION V: EVACUATION

SECTION VI: SYSTEM CHARGE

MEASURE INDOOR AIR FLOW

Procedure for determining correct indoor airflow for system performance.

CHARGING THE UNIT

Instructions and warnings for charging the system with refrigerant.

CHARGING IN HEATING MODE

Methods for charging heat pumps in heating mode.

CHARGING WITH GAUGES

Using gauges for charging and verifying pressure readings.

SECTION VII: ELECTRICAL CONNECTIONS

GENERAL INFORMATION & GROUNDING

Electrical supply requirements and grounding procedures.

FIELD CONNECTIONS POWER WIRING

Steps for making power wiring connections to the unit.

FIELD CONNECTIONS CONTROL WIRING

Procedure for connecting low voltage control wiring.

ROUTE CONTROL WIRING

Routing 24-volt control wiring to the unit and thermostat.

DEHUMIDIFICATION CONTROL (TYPICAL)

Details on installing and configuring a dehumidification control accessory.

SECTION VIII: SYSTEM START-UP

ENERGIZE CRANKCASE HEATER

Procedure for energizing the crankcase heater before start-up.

INDOOR CUBIC FEET PER MINUTE (CFM) SELECTION BOARD SETTINGS

Configuring CFM selection board jumpers for proper system operation.

WITH POWER TO UNIT AND THERMOSTAT IN COOLING POSITION

Steps for starting the unit in cooling mode with thermostat.

SECTION IX: SYSTEM OPERATION

SECTION X: INSTRUCTING THE OWNER

MAINTENANCE

Guidelines for cleaning and maintaining the outdoor unit and components.

SECTION XI: WIRING DIAGRAM

SECTION XII: START UP SHEET