397763-YTG-B-0508
Johnson Controls Unitary Products 15
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.
THGD48S41S1
PV8*C16 FC/MC/PC48C 50.0 3.28 4.47 30.6 2.24 4.00 8.00
PV8*C20 FC/MC/PC48C 50.5 3.34 4.43 30.6 2.26 3.97 8.00
P(C,V)9*C16 FC/MC/PC48C 50.5 3.32 4.46 30.8 2.24 4.03 8.00
P(C,V)9*C20 FC/MC/PC48C 50.5 3.34 4.43 30.6 2.26 3.97 8.00
P(C,V)9*D20 FC/MC/PC48D 50.0 3.38 4.34 30.6 2.28 3.93 8.00
PV8*C16 FC/MC/PC60C 50.5 3.50 4.23 30.4 2.34 3.81 8.00
PV8*C20 FC/MC/PC60C 50.5 3.56 4.16 30.4 2.38 3.74 8.00
P(C,V)9*C16 FC/MC/PC60C 51.0 3.52 4.25 30.6 2.34 3.83 8.00
P(C,V)9*C20 FC/MC/PC60C 50.5 3.54 4.18 30.4 2.36 3.78 8.00
P(C,V)9*D20 FC/MC/PC60D 50.5 3.58 4.13 30.2 2.38 3.72 8.00
P(C,V)9*D20 HC60D 50.5 3.58 4.13 30.2 2.38 3.72 8.00
PV8*C16 HD60C 49.5 2.94 4.93 30.4 2.04 4.37 8.00
PV8*C20 HD60C 49.5 3.02 4.80 30.4 2.08 4.28 8.00
P(C,V)9*C16 HD60C 50.0 2.98 4.92 30.6 2.06 4.35 8.00
P(C,V)9*C20 HD60C 49.5 3.00 4.84 30.4 2.06 4.33 8.00
P(C,V)9*D20 HD60D 49.5 3.04 4.77 30.2 2.08 4.26 8.00
PV8*C20 MC62C 50.5 3.42 4.33 30.4 2.30 3.87 8.00
P(C,V)9*C16 MC62C 50.5 3.38 4.38 30.6 2.28 3.93 8.00
P(C,V)9*C20 MC62C 50.5 3.40 4.35 30.4 2.30 3.87 8.00
P(C,V)9*D20 MC62D 50.0 3.44 4.26 30.2 2.32 3.82 8.00
THGD60S41S1
PV8*C20 MC62C 56.5 3.52 4.70 35.2 2.44 4.23 8.00
P(C,V)9*C20 MC62C 56.5 3.44 4.81 35.2 2.42 4.26 8.00
P(C,V)9*D20 MC62D 56.0 3.46 4.74 35.0 2.42 4.24 8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT
MODEL
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47°F17°FHSPF
MBH COP KW MBH COP KW STD