5855836-YTG-B-1121
4 Johnson Controls Ducted Systems
SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS - N COIL
Outdoor unit YEE18B21S YEE24B21S YEE30B21S YEE36B21S YEE42B21S YEE48B21S YEE60B21S
Required indoor
metering device
1,2
1. For applications that require a TXV, use S1-1TVM*** series kit.
2. Approved orifice(s) are shipped with the outdoor unit.
BA1 BA1 BA1 BA1 BC1 BC1 BC1
Defrost jumper pin setting 2222222
Indoor unit
3,4,5
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower time delay.
4. Do not use CF coils in horizontal applications.
5. Charge adders shown above do not indicate that coils are rated for every application. See the Performance Data tables for actual performance for specified system
matches. Obtain certified system ratings from
www.ahridirectory.org.
Additional charge (oz)
AE18B 3 ——————
AE24B 6 —————
AE30B 17 ————
AE36(B,C) 5
AE42C ————16——
AE43C ———————
AE48(C,D) ————160
AE60C ———————
AE60D ——————18
AVC18B 3 ——————
AVC24B 6 —————
AVC30B 17 ————
AVC36(B,C) 5
AVC42C ————16——
AVC48(C,D) ————160
AVC49C ———————
AVC60C ———————
AVC60D ——————18
CF/CM/CU18(A,B) 3 ——————
CF/CM/CU24(B,C) 6 —————
CF/CM/CU30(A,B,C) 17 ————
CF/CM/CU36(B,C,D) 5
CF/CM/CU42(B,C,D) ———————
CF/CM/CU48(C,D) ————160
CF/CM/CU60(C,D) ———————
CF/CM64D —————— 7
Note: Some of the combinations shown in this table require advanced main air-circulating fan indoor products. For approved coil-only matches, see
the SYSTEM CAPACITY - With High Efficiency Motor Furnaces table.