17
Installation procedure
NO
VT wire
Drain hose
Piping hole
Base (Bottom)
Intake grill
VT wire hole
Pass the drain hose through here
Cut the grill
Fig.16
5. Installing the drain hose
OK
Fig.15
Removetheholecover.
Arrange the drain hose
lower than this portion
Drain hose
Select whether the drain hose will be connected to the
left or right side.(Fig.2)
Insert the drain hose into the drain pan, then secure
the drain hose with a nylon fastener.(Fig.4)
Wrap the insulation (drain hose) around the drain hose
connection. (Fig.5)
Be sure to arrange the drain hose correctly so that it is
leveled lower than the drain hose connecting port of
the indoor unit. (Fig.11)
When drain hose is arranged backward. Secure the
drain hose with the VT wire. (Fig.16)