5523949-YTG-J-0620
Johnson Controls Ducted Systems 9
3. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
* Notates “Hot Heat Pump” performance. These ratings are not AHRI listed.
MP Modular Air Handlers use Coil Only Ratings.
YHE48B22S AE48CX21 21.0 1400 46.0 31.8 14.25 12.00 47.5 31.4 9.00 3.58 2.64
YHE48B22S AE48DBC21 24.5 1400 46.5 32.0 14.5 12.25 47.5 31.4 9.00 3.62 2.66
YHE48B22S AE48DX21 24.5 1400 46.5 32.0 14.5 12.25 47.5 31.4 9.00 3.62 2.66
YHE48B22S AVC48CX21 21.0 1375 46.0 31.6 14.25 12.00 47.5 31.4 9.00 3.56 2.62
YHE48B22S AVC48DX21 24.5 1400 46.5 31.6 14.75 12.25 47.5 31.2 9.00 3.60 2.66
YHE48B22S AVC60CX21 21.0 1350 46.5 31.6 15.00 12.50 47.5 31.2 9.00 3.56 2.62
YHE48B22S ME14DN21 24.5 CF/CM48D 1400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 3.60 2.66
YHE48B22S ME14DN21 24.5 CF/CM60D 1400 46.5 32.0 14.25 12.00 48.0 31.4 9.00 3.54 2.60
YHE48B22S ME14DN21 24.5 CM48DBCA1 1400 46.5 32.0 14.50 12.25 47.5 31.4 9.00 3.60 2.66
YHE48B22S ME16CN21 21.0 CF/CM48C 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.58 2.64
YHE48B22S ME16CN21 21.0 CF/CM60C 1400 47.0 32.2 14.50 12.25 47.5 31.2 9.00 3.58 2.62
YHE48B22S ME16CN21 21.0 CF48CBCA1 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.58 2.64
YHE48B22S ME16CN21 21.0 CM48CBCA1 1400 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.58 2.64
YHE48B22S ME20DN21 24.5 CF/CM48D 1400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.66
YHE48B22S ME20DN21 24.5 CF/CM60D 1400 47.0 32.2 14.75 12.25 47.5 31.2 9.00 3.58 2.64
YHE48B22S ME20DN21 24.5 CM48DBCA1 1400 46.5 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.66
YHE48B22S MVC16CN21 21.0 CF/CM48C 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.64
YHE48B22S MVC16CN21 21.0 CF48CBCA1 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.64
YHE48B22S MVC16CN21 21.0 CM48CBCA1 1425 46.0 31.8 14.50 12.00 47.5 31.4 9.00 3.60 2.64
YHE48B22S MVC20DN21 24.5 CF/CM48D 1350 46.5 32.0 14.50 12.25 47.5 31.2 9.00 3.62 2.68
YHE48B22S MVC20DN21 24.5 CF/CM60D 1475 47.5 33.2 15.00 12.50 47.5 31.4 9.00 3.64 2.66
YHE48B22S MVC20DN21 24.5 CM48DBCA1 1350 46.5 32.0 14.50 12.25 47.5 31.2 9.00 3.62 2.68
YHE60B22S AE60DBG21 24.5 1650 55.5 38.6 14.00 12.00 57.0 37.8 9.00 8.65 3.88 2.82
YHE60B22S AE60DX21 24.5 1650 55.5 38.6 14.00 12.00 57.0 37.8 9.00 8.65 3.88 2.82
YHE60B22S AVC60DX21 24.5 1550 55.5 39.5 14.25 12.00 57.0 37.8 9.00 3.88 2.82
YHE60B22S ME20DN21 24.5 CF/CM64D 1600 55.0 38.0 14.25 12.00 57.0 37.6 9.25 3.88 2.82
YHE60B22S MVC20DN21 24.5 CF/CM64D 1600 55.5 38.5 14.25 12.00 57.0 37.6 9.25 3.90 2.82
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
1. Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
2. Heating MBH based on AHRI standards of 70°F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
COP (Coefficient of Performance) equals Heating MBH output divided by (total KW input x 3.412).
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
UNIT
MODEL
AIR HANDLER
COIL
MODEL
3
RATED
CFM
COOLING
1
HEATING
2
MODEL WIDTH
NET MBH
SEER EER
NET MBH
HSPF
Region IV
HSPF
Region V
COP
TOTAL SENS. 47°F OD 17°F OD 47°F OD 17°F OD