EasyManua.ls Logo

York YHJD18 User Manual

York YHJD18
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL GUIDE
SPLIT-SYSTEM HEAT PUMPS
13 SEER – R-410A
MODELS:
YHJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS - 1PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
10-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
LISTED
397855-YTG-G-0509
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
Quality Condenser Coils - The coil is constructed of copper
tubing and enhanced aluminum fins for increased efficiency
and corrosion protection.
Protected Compressor - The compressor is internally pro-
tected against high pressure, temperature, and externally by
a factory installed high pressure switch. This is accomplished
by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if
undesirable operating conditions occur. A liquid line filter-
drier further protects the compressor.
Durrable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
Top Discharge - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York YHJD18 and is the answer not in the manual?

York YHJD18 Specifications

General IconGeneral
BrandYork
ModelYHJD18
CategoryHeat Pump
LanguageEnglish

Summary

York Technical Guide Overview

Product Description

Details the 13 SEER Series unit as the outdoor component of a versatile climate system.

Key Unit Features

Highlights benefits like quality condenser coils, protected compressor, durable finish, and low operating sound.

Available Unit Accessories

Start Assist Kit

May be required for specific models to provide starting torque.

Blower Time Delay

Improves efficiency by maintaining blower operation after cooling thermostat is satisfied.

Hard Start Kits

Provides required starting torque for use with Thermal Expansion Valve Kits.

Low Temperature Cutout

Prevents heat pump operation below -10°F ambient temperature.

Compressor Blanket

Designed to further reduce the normal operating sound of the unit.

Add-on Fossil Fuel Control

Interface controls for use with gas, oil furnaces and heat pump systems.

Thermal Expansion Valve Kit

TXV kit used to improve system performance and efficiency.

Typical Unit Installation Guidelines

Outdoor Unit Clearance Requirements

Specifies minimum clearances for overhead, service access, and perimeter.

Field Wiring Diagrams and Instructions

Thermostat and Indoor Unit Wiring

Details low-voltage wiring connections for thermostat to indoor unit.

Outdoor Unit Power and Control Wiring

Explains power wiring and control wiring for the outdoor unit.

Related product manuals