Johnson Controls Unitary Products 19
246750-YTG-M-0908
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
G*9V*A12 FC/MC/PC32A 14
1 625 18.7 - - 3.10
2 800 24.0 15.7 8.00 3.28
2 625 22.8 14.7 7.90 3.14
G*9V*A12 FC/MC/PC36A 14
1 625 18.9 - - 3.16
2 800 24.0 15.6 8.20 3.34
2 625 22.9 14.6 8.00 3.18
G*9V*B12 FC/MC/PC35B 17
1 550 18.3 - - 3.04
2 815 24.0 15.5 8.20 3.34
2 550 22.2 14.6 7.90 3.04
G*9V*B12 FC/MC/PC36B 17
1 590 18.2 - - 3.14
2 815 24.0 15.2 8.30 3.40
2 590 21.5 14.2 7.60 3.10
G*9V*A12 FC/MC/PC37A 14
1 535 18.7 - - 3.04
2 800 25.6 15.6 8.90 3.52
2 535 22.8 14.6 8.10 3.05
G*9V*B12 FC/MC/PC43B 17
1 550 18.6 - - 3.10
2 800 24.0 15.5 8.30 3.42
2 550 21.4 14.4 7.60 3.04
G*9V*A12 HC30 14
1 625 18.8 - - 3.06
2 800 23.8 15.6 8.10 3.24
2 625 22.7 14.5 7.90 3.09
G*9V*A12 HD36 14
1 625 17.0 - - 2.50
2 800 24.2 15.1 8.20 2.80
2 625 21.7 14.9 7.50 2.46
G*9V*B12 HD36 17
1 590 17.1 - - 2.42
2 815 24.2 15.0 8.40 2.86
2 590 21.5 15.8 7.60 2.39
G*9V*A12 UC24A 14
1 625 18.9 - - 3.14
2 800 24.0 15.6 8.20 3.32
2 625 22.6 14.7 7.90 3.18
G*9V*B12 UC24B 17
1 565 18.7 - - 3.16
2 790 24.0 15.3 8.30 3.36
2 565 21.5 14.4 7.60 3.09
G*9V*A12 UC30A 14
1 625 18.9 - - 3.14
2 800 24.0 15.6 8.20 3.32
2 625 22.6 14.7 7.90 3.18
G*9V*B12 UC30B 17
1 565 18.7 - - 3.10
2 790 24.0 15.5 8.30 3.34
2 565 21.4 14.4 7.60 3.04
G*9V*A12 UC36A 14
1 625 17.5 - - 3.00
2 800 23.8 14.1 8.10 3.24
2 625 22.0 12.9 7.60 3.14
G*9V*B12 UC36B 17
1 590 16.3 - - 2.66
2 815 23.8 14.1 8.20 3.30
2 590 22.2 13.2 7.90 3.12
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - YZE02411With Variable Speed Furnaces (Continued)
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
13 SEER HP WITH VARIABLE SPEED FURNACES
3