Johnson Controls Unitary Products 29
246750-YTG-M-0908
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
G*9V*C20 HD60 21
1 1055 31.2 - - 3.30
2 1655 48.0 27.2 8.50 3.68
2 1055 44.7 26.2 8.00 3.40
G*9V*D20 HD60 24
1 1070 31.4 - - 3.30
2 1615 48.0 27.2 8.60 3.70
2 1070 44.7 26.2 7.90 3.40
G*9V*C16 UC48C 21
1 1050 32.4 - - 3.68
2 1540 48.5 28.0 8.70 3.90
2 1050 48.7 27.2 8.60 3.80
G*9V*C20 UC48C 21
1 1055 32.2 - - 3.60
2 1445 48.5 27.8 8.70 3.86
2 1055 48.8 27.1 8.50 3.69
G*9V*D20 UC48D 24
1 1060 32.4 - - 3.70
2 1645 48.5 27.8 8.70 3.96
2 1060 48.8 27.2 8.60 3.82
G*9V*C16 UC60C 21
1 1050 32.4 - - 3.66
2 1590 48.5 27.8 8.70 3.96
2 1050 49.1 27.1 8.60 3.80
G*9V*C20 UC60C 21
1 1055 32.4 - - 3.68
2 1655 48.5 27.8 8.70 3.96
2 1055 49.0 27.0 8.60 3.81
G*9V*D20 UC60D 24
1 1070 32.4 - - 3.68
2 1615 48.5 27.8 8.80 3.98
2 1070 49.1 27.0 8.60 3.81
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - YZE04811With Variable Speed Furnaces (Continued)
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
13 SEER HP WITH VARIABLE SPEED FURNACES
3
HEATING CAPACITY - YZE06011With Variable Speed Furnaces
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
13 SEER HP WITH VARIABLE SPEED FURNACES
3
PV8*C20 FC/PC/UC60C 21
1 1030 37.0 - - 3.22
2 1730 54.5 32.0 8.05 3.48
2 1030 49.5 29.6 7.85 3.20
P(C,V)9*C20 FC/PC/UC60C 21
1 990 36.8 - - 3.20
2 1640 54.5 31.6 8.00 3.46
2 990 49.5 29.2 7.80 3.18
P(C,V)9*D20 FC/MC/PC/UC60D 24
1 990 36.8 - - 3.20
2 1620 54.0 31.4 8.00 3.46
2 990 49.0 29.0 7.75 3.16
P(C,V)9*D20 FC/MC62D 24
1 990 36.8 - - 3.20
2 1620 54.0 31.4 8.00 3.48
2 990 49.0 29.0 7.75 3.16
For Notes, See Page 31.