York YZF - Thermostat Wiring - Single Stage Heat Pump (with YGVI Control) - Single Stage Furnace (X-13)

York YZF
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
835966-UIM-E-0814
Johnson Controls Unitary Products 11
FIGURE 11: Thermostat Wiring – Single Stage Heat Pump (with YGVI control) – Single Stage Furnace (Standard ECM)
A007-001
TM9E
TM9X
T*(8,L)X
Single Stage Heat Pump (with YGVI control) - Single Stage Furnace (S-ECM)
ID MODELS
Y1
First Stage Compressor
Y1
First Stage Compressor
Y1
Single Stage
Compressor
Change “FFuel” jumper
on the heat pump control
to “ON”
Jumper 1 must be
set to “HEAT PUMP”
Jumper 2 must be
set to “O”
Jumper 3 must be
set to “GAS”
Setup Step 50 “Dual
Fuel” must be set
“External”
Suggestion: Set setup
step 26 “2nd Stage
Deadband” and step 29
“Minutes Between 1st
and 2nd” to 0.
Bonnet Sensor Kit
(Optional)
S1-37309243000
BS
Bonnet Sensor
BSG
Bonnet Sensor
W
Auxiliary Heat
Y2
Second Stage
Compressor
X/L
Malfunction Light
O
Reversing Valve
Energized In Cool
Y2 OUT
Second Stage
Compressor
W2 OUT
Second Stage Heat
W1 OUT
First Stage Heat
R
24 - Volt Hot
C
24 - Volt Common
C
24 - Volt Common
R
24 - Volt Hot
G
Fan
W
First Stage Heat
Y/Y2
Second or Full
Stage Compressor
C
24 - Volt Common
R
24 - Volt Hot
G
Fan
Fault
W3
Third Stage Heat
Y2
Second Stage
Compressor
W2
Second Stage Heat
W1/O/B
First Stage Heat
HUM
DHUM
THERMOSTAT
S1-THSU32HP7b
SINGLE STAGE
FURNACE (S-ECM)
SINGLE STAGE
HEAT PUMP
YORKGURARD VI
CONTROL
SINGLE STAGE
FURNACE (S-ECM)