Page 1
06201-90(K)
MODEL 06201
WIND TRACKER
SPECIFICATIONS
Size:
144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in)
Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in)
Sensors: Wind Monitor (05), Wind Monitor-AQ (05A), Wind
Monitor-SE (09), Ultrasonic Anemometer (09), Wind
Monitor-JR (04), Wind Sentry (03), Wind Monitor
HD (Hd)
Accuracy: ±0.6% Full Scale
Serial I/O: Proprietary binary I/O for master-remote display or
simple ASCII text output for external device: ss.s
ddd<cr><lf>
ss.s windspeed (m/s)
ddd wind direction in degrees
RS-485 half-duplex, 9600 baud,
8-1-n, no handshaking
Other inputs: 4-20 mA (0-360 deg, Ldi 0-50 m/s, Ld2 0-100 m/s)
Other outputs: 0-5 VDC = 0-360° or 0-540°
0-5 VDC = 0-100 m/s
Alarm Relays: Normally Open contacts for WS and WD Contact
rating 24 VAC or 30 VDC maximum 5A resistive,
2A inductive maximum
Input Power: 12-30 VDC, 3.5 W
Weight: 1.0 lb (0.45 kg) without AC adapter
INTRODUCTION
The YOUNG Model 06201 Wind Tracker is a compact wind speed
and direction display with advanced features for use in a wide range
of applications.
FEATURES
3-digit wind speed display
3-digit maximum wind speed or wind direction display
Multi-color wind direction display with variability
Wind speed and direction alarms with delay
RS-485 serial connections
Calibrated 0-5 VDC outputs
Display brightness control
PRECAUTIONS
INDOOR USE ONLY!
(Unless placed in approved enclosure)
Operating temperature range:
0-50°C (32-122°F), 0-95% RH
Use only recommended power sources.
(12-30 VDC, 3.5 W )
Disconnect power when connecting or servicing
Alarm contact rating 24 VAC/30 VDC,
(5 A resistive, 2 A inductive maximum)
MOUNTING AND START-UP
1. For best visibility, place the Wind Tracker in a location free of
direct sunlight. Mount it using the attached bracket or remove
bracket for ush mounting to a bulkhead or panel cutout. Panel
cutout dimensions are given in the specications. An optional
rack mounting panel (Model 06280) and protective enclosure
(Model 06260) are available from your YOUNG supplier.
2. Connect cables to terminals according to wiring diagram.
IMPORTANT NOTE! Please observe correct position of back
panel Input Selector Switch according to wiring diagram.
3. Connect GND terminal to suitable earth ground.
4. Insert power supply plug into power jack, plug power supply into
a suitable AC wall outlet or connect to suitable 12 to 30 VDC
power source to terminals.
IMPORTANT NOTE! Do not connect more than one power
source to the Wind Tracker at the same time.
5. When power is applied, the Wind Tracker will display rmware
version number then begin to display wind information as follows:
Wind speed
Wind speed units
Maximum wind speed or direction degrees
Wind direction (single orange indicator)
Direction variability (green indicators)
Alarm status indicators (if selected)
Wind speed & direction averaging indicator (if selected)
6. Observe display to conrm proper operation.