EasyManua.ls Logo

Z-Wave Aeotec 7 Pro - Screw Terminal; Link testing; Scene Controller

Z-Wave Aeotec 7 Pro
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Screw Terminal
The product must support the interconnection of external binary sensors as well as actuators
and dry-contacts. The product allows interconnection with external sensors/actuators via 3-pin
screw terminals with the following pinout:
#1: Ground
#2: Digital Input
#3: VCC (direct battery supply)
VCC + Ground terminals can be used to externally power the sensor with a 3.6V battery or special power
adapter (which is not included in the scope of delivery). Digital + VCC is used to connect the external dry
contact.
Link testing
When activated by configuration parameter #5 the device can perform a link test. Double-clicking the
tamper will start the process. As a result, the GREEN LED will blink two times in case of success and the
RED LED will blink two times in case of failure.
Scene Controller
When activated by configuration parameter #14 the device can perform as a scene controller. Digital +
VCC is used to connect the scene button. The external dry contact will then act as a scene controller with
a total of 7 scenes that can be activated:
1 - Contact Pressed 1 time
2 - Contact Pressed 2 time
3 - Contact Pressed 3 time
4 - Contact Pressed 4 time
5 - Contact Pressed 5 time
6 - Contact held down
7 - Contact released
The device sends the following notifications to the central controller:
Window Opened(0x06 - 0x16)
Window Closed(0x06 - 0x17)
Tamper Removed(0x07 - 0x03)
The device sends the following sensor binary reports to the controller:
Tilt(0x0B)
Node Information Frame