Parameter 24: Report battery report at an interval set in hour
Size: 1 Byte, Default Value: 24
Setting
Description
0
Disable
1
-
255
1
-
2
55 hours
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults
Size: 4 Byte, Default Value: 0
Setting
Description
1
-
1431655764
Reset all Parameter settings to their
default settings.
1431655765
Completely factory reset sensor and send device reset locally
notification.
Technical Data
Dimensions
28x95x35 mm
Hardware Platform
ZGM130S
IP Class
IP 20
Battery Type
1 * 1/2 AA
Device Type
Notification Sensor
Generic Device Class
Sensor Notification
Specific Device Class
Routing Sensor Notification
Network Operation
Reporting Sleeping Slave
Firmware Version
02.00
Z
-
Wave Version
07.15
Z
-
Wave Product Id
0371.0002.000C
Frequency
Europe - 868,4 Mhz
Maximum transmission
power
5 mW