7
English
2. Technical Specifications
Electrical
Parameter Test condition Min Typ Max Unit
Standby power
consumption
3 W
Maximum charging power
TN 3 phase @ 32 A 22
kW
TN 1 phase @ 32 A 7.4
IT 3 phase @ 32 A 12.7
IT 1 phase @ 32 A 7.4
Connectivity
Protocol Supported standards
4G LTE Cat M1
Wi-Fi 802.11b/g/n (2.4 GHz)
Bluetooth Bluetooth v5.1 (BR/EDR/BLE)
Powerline (PLC) HomePlug Green PHY, 10 Mbit/s
Plug and charge Hardware support for ISO15118
RFID ISO/IEC 14443 A (Type A, 13.56 MHz)
ISO/IEC 15693 (Mifare classic, 13.56 MHz)
Integrated energy meter
Parameter Test condition Min Typ Max Unit
Accuracy
Line voltage, current,
and power factor
-2 2 %
Line voltage, current,
power factor and
temperature
-3 3 %
MID model only: integrated energy meter
Parameter Value
Certification MID Class B
Harmonized Standard EN 50470-12006, EN 50470-32006
Notified Body Justervesenet (0431) / NMi Certin (0122)
Rated Voltage 3 × 230/400 V
Rated Current 0.25-5 (32) A
Optical Test Output (must be activated in the app) 10000 imp/kWh