EasyManua.ls Logo

Zephyr Pisa ZPI-E30BG - Venting and Filter Issues

Zephyr Pisa ZPI-E30BG
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Pisa Use, Care, and Installation Guide
PISA
UNDERCABINET
CORE
Troubleshooting
The hood is not venting
out properly.
Using the wrong size of ducting. Change the ducting to the correct size.
The hood might be hanging to high
from the cook top.
Adjust the distance between the cook top
and the bottom of the hood within 20”
(electric cook tops) or 24” (gas cook tops)
and 32” range.
The wind from the opened windows
or opened doors in the surrounding
area are aecting the ventilation of
the hood.
Close all the windows and doors to eliminate
the outside wind flow.
Blockage in the duct opening or
ductwork.
Remove all the blocking from the duct work
or duct opening.
Filter is vibrating. Filter is loose. Adjust or change the filter.
Spring clip is broken on the filter. Change the spring clip.
Possible Problem Possible Cause Solutions

Related product manuals