EasyManua.ls Logo

Zephyr Cyclone AK6500BS - User Manual

Zephyr Cyclone AK6500BS
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WWW.ZEPHYRONLINE.COM
SEP20.0701
Typhoon
AK2100CS, B, W
AK2136CS, B, W
AK2142CS
AK2148CS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
Hurricane
AK2500BS, B, W
AK2536BS, B, W
Cyclone
AK6500BS, B, BS, W
AK6536BS, B, BS, W
AK6542BS
Airflow Control Technology
TM
C
C
Airflow Control Technology
TM
C
C

Questions and Answers

  • D
    David JenkinsSep 10, 2025
    Why is my Zephyr Cyclone AK6500BS Ventilation Hood vibrating?
    • X
      xschroederSep 10, 2025
      If your Zephyr Ventilation Hood is vibrating, it could be due to a few reasons. Check that the blower is securely tightened in place. Another cause may be a damaged blower wheel, which would need to be replaced. Also ensure that the hood itself is properly secured in place by verifying its installation.
  • F
    Frederick DavisAug 22, 2025
    What to do if my Zephyr Cyclone AK6500BS Ventilation Hood doesn't work after installation?
    • Q
      qgillAug 23, 2025
      If your Zephyr Ventilation Hood doesn't work after installation, check the following: Ensure the power source is turned ON by verifying the circuit breaker and unit's power are ON. Check that the power line and cable locking connector are properly connected to the unit. Make sure the wirings at the switch board and control board are connected correctly. If the switch board or control board is defective, it should be replaced.
  • M
    Michelle WheelerAug 25, 2025
    What to do if my Zephyr Cyclone AK6500BS Ventilation Hood turns on by itself?
    • R
      Ryan Riley MDAug 25, 2025
      If your Zephyr Ventilation Hood turns on by itself, it might be because a spotlight or kitchen lamp is shining directly onto the switch controls. These controls are light sensitive, and a direct light source may disrupt their function.
  • A
    Amy Williams DDSAug 26, 2025
    What to do if my Zephyr Ventilation Hood is not venting out properly?
    • J
      jbaldwinAug 26, 2025
      If your Zephyr Ventilation Hood isn't venting out properly, several factors could be the cause. Ensure you're using solid, rigid metal ducting, as flexible ducting can significantly reduce airflow. Check that the hood is positioned correctly, maintaining a distance between 24” and 32” from the cooktop. Eliminate any external wind by closing nearby windows and doors. Finally, inspect the ductwork and opening for any blockages.
  • C
    Christy WernerAug 27, 2025
    Why is my Zephyr Cyclone AK6500BS not working after installation?
    • J
      Jaime LopezAug 27, 2025
      If your Zephyr Ventilation Hood isn't working after installation, start by ensuring that the circuit breaker and the unit's power are turned ON. Then, check the power connection to confirm it's properly connected. Also, verify that the wirings at the switch board and control board are securely connected. If the issue persists, the switch board or control board might be defective and require replacement.
  • E
    emckenzieAug 29, 2025
    What to do if my Zephyr Cyclone AK6500BS Ventilation Hood light works, but the blower isn't turning?
    • P
      pjonesAug 29, 2025
      If the light on your Zephyr Ventilation Hood is working, but the blower isn't turning, there are several potential causes. First, check the blower cable to ensure it is properly connected. Next, inspect the motor for any debris or obstructions that may be preventing it from turning. If those aren't the issue, the motor or capacitor may be defective and require replacement. Finally, the switch board or control board could be defective, requiring you to change the defective part.
  • P
    Paul SmithSep 18, 2025
    What to do if the safety grille is vibrating on my Zephyr Cyclone AK6500BS Ventilation Hood?
    • M
      Melissa PittsSep 18, 2025
      If the safety grille on your Zephyr Ventilation Hood is vibrating, it is likely that the safety grille is loose. To fix this, simply tighten the safety grille screw.
  • V
    Vanessa BlevinsSep 12, 2025
    How to fix a vibrating safety grille on my Zephyr Cyclone AK6500BS Ventilation Hood?
    • R
      Randall RoblesSep 12, 2025
      If the safety grille on your Zephyr Ventilation Hood is vibrating, it is likely because the safety grille is loose. To resolve this, simply tighten the safety grille screw.
  • K
    Kaitlyn BarnettSep 8, 2025
    What to do if my Zephyr Ventilation Hood doesn’t work after installation?
    • P
      Phillip CraneSep 8, 2025
      If your Zephyr Ventilation Hood doesn’t work after installation, first ensure that the power source is turned ON by checking the circuit breaker and the unit's power. Then, verify that the power line and cable locking connector are properly connected. Also, check the wirings at the switch board and control board to ensure they are connected correctly. If the problem persists, the switch board or control board may be defective and need to be replaced.
  • B
    Brian JenkinsSep 5, 2025
    What to do if my Zephyr Cyclone AK6500BS light works but the blower isn't turning?
    • M
      Monique GarnerSep 5, 2025
      If the light works, but the blower isn't turning on your Zephyr Ventilation Hood, several issues could be the reason. Start by checking the blower cable to ensure it's properly connected. Also, inspect the motor for any debris or obstructions that may be preventing it from turning. If those aren't the problem, the motor may be defective or seized, the capacitor might be damaged, or the switch board or control board could be defective, requiring you to change the defective part.

Summary

Safety Information

Safety Warning Levels

Explains DANGER, WARNING, CAUTION symbols and meanings.

General Safety Precautions

Essential safety rules for using the appliance.

Grease Fire Prevention

Steps to mitigate risks of grease fires during cooking.

Electrical and Installation Safety

Safety guidelines for electrical wiring and installation.

Operation and Electrical Requirements

Safe operation practices and power connection needs.

Grounding and Wiring Details

Information on proper grounding and electrical supply.

List of Materials

Included Parts List

Lists all components provided with the hood.

Required Parts Not Included

Lists items needed but not supplied with the hood.

Ducting Calculation Sheet

Ducting Calculation Worksheet

Tool to calculate total duct length for optimal airflow.

Mounting Height, Clearance, & Ducting

Mounting Height & Clearance

Specifies optimal height and clearance for installation.

Ducting Requirements

Details ducting size and types for efficient airflow.

Ducting Options

Ducting Configurations and Warnings

Illustrates ducting methods and associated fire hazards.

AK21 Hood Specifications

AK21 Dimensions and Specs

Detailed dimensions and specs for the AK21 model.

AK25 Hood Specifications

AK25 Dimensions and Specs

Detailed dimensions and specs for the AK25 model.

AK65 Hood Specifications

AK65 Dimensions and Specs

Detailed dimensions and specs for the AK65 model.

Electrical Supply

Electrical Supply & Cable Lock

Requirements for power connection and cable security.

Rectangular Vertical Ducting Preparation

Vertical Ducting Prep Steps

Steps to prepare for vertical rectangular ducting.

Rectangular Horizontal Ducting Preparation

Horizontal Ducting Prep Steps

Steps to prepare for horizontal rectangular ducting.

Rectangular Horizontal Ducting Preparation - Continued

Horizontal Ducting Prep Steps (Cont.)

Continues the steps for horizontal rectangular ducting.

Mounting the Hood

Hood Mounting Components & Diagram

Visual guide showing parts and process for mounting.

Mounting the Hood - Continued

Hood Mounting Installation Steps

Step-by-step guide for installing the hood.

AK21 Capacitive Touch

Controls Overview

Explains operation of AK21 touch controls.

ACT Verification

How to verify Airflow Control Technology settings.

AK25 Electronic Touch

Controls Overview

Explains operation of AK25 electronic touch controls.

AK65 Mechanical Slide

Controls Overview

Explains operation of AK65 mechanical slide controls.

ACT Availability Note

States ACT is not available for AK65 models.

Maintenance

Hood & Filter Cleaning

Instructions for self-cleaning feature and residue cups.

Cleaning Frequency & Detergents

Guidance on cleaning intervals and suitable cleaning agents.

Maintenance - Continued

Hood & Filter Cleaning Steps

Detailed steps for cleaning the hood and filters.

Maintenance - Continued

Surface Cleaning

How to clean stainless steel surfaces without damage.

LumiLight LED & LED Light Strip

LED Light Replacement Procedure

Steps for removing and replacing LED lights.

ACT Conversion

Airflow Control Technology Explained

Overview of ACT for controlling fan CFM.

ACT Conversion Safety

Critical safety warnings before performing ACT conversion.

ACT Conversion - Continued

Enabling and Setting ACT

Guide to enable ACT and set CFM levels.

Verifying ACT Settings

How to confirm ACT is enabled and its CFM setting.

ACT Conversion - Continued

Accessing PC Board for ACT

Instructions to access the PC board for conversion.

Wiring Diagram

AK2100;36;42;48 C Wiring

Electrical diagram for AK2100 series models.

AK2500;36 B Wiring

Electrical diagram for AK2500 series models.

AK6500;36;42 B Wiring

Electrical diagram for AK6500 series models.

Troubleshooting

Common Problems and Solutions

Addresses frequent issues and provides solutions.

List of Parts & Accessories

Replacement Parts & Optional Accessories

Lists parts for replacement and optional add-ons.

Notes

User Notes

Blank space for personal notes.

Notes

User Notes

Blank space for personal notes.

Limited Warranty

Warranty Terms and Exclusions

Details warranty coverage, limitations, and exclusions.

Product Registration

Benefits of Product Registration

Explains why registering the product is important.

Zephyr Cyclone AK6500BS Specifications

General IconGeneral
Colorstainless steel
Hood Typeunder cabinet
Venting Typeducted
Number of Fan Speeds3
Interior Lightyes
Voltage120 volts
Current2.4 amperes
Weight and Dimensions IconWeight and Dimensions
Depth22 1/5 inches
Height6 2/5 inches
Width29 4/5 inches
Net Weight64.7 pounds

Related product manuals