Revision Date – 15/07/2020 page 48
9.11 Plug fuse (12/24V DC) - Replace
Disconnect the 12/24V DC power lead from all
power supplies.
Unscrew end of plug from housing.
Separate plug and housing. Remove fuse from
plug.
Replace the device fuse with a new fuse of the
same rating. Fuse rating DC Glass 12/24V
10Amp – 6G10A.
Reassemble the plug and test for continuity.
9.12 Device fuse (100-240V AC) - Replace
Remove the AC and DC power leads from the
power sockets.
Remove the fuse insert from the rear panel of the
fridge as shown.
HINT: A small flat blade screwdriver may be
required to help pry the insert away from
its housing.
Replace the defective fuse with a new fuse that
has the same rating. The correct rating for the
fuse is 6.3A, specified as: F6.3L250V.
Replace the fuse insert back into its housing
Remove fuse insert