ZGR TOWER PRO 1 3 KVA
Operation manual
www.zigor.com
9
The complete rage is shown in the following table:
MODEL
POWER
BATTERY PLACEMENT
ZGR TOWER PRO 1 KVA
1 KVA
Internal
ZGR TOWER PRO 2 KVA
2 KVA
ZGR TOWER PRO 3 KVA
3 KVA
ZGR TOWER PRO 1 KVA LBT
1 KVA
External
ZGR TOWER PRO 2 KVA LBT
2 KVA
ZGR TOWER PRO 3 KVA LBT
3 KVA
Table 2-1 ZGR TOWER PRO 1-3 KVA series range
BT
inside them but with a reinforced battery charger. These models are normally used for high backups and they are
accompanied by battery cabinets.
Main characteristics
Low distortion sinusoidal output voltage: a modern inverter with modulation control of the pulse width
(PWM) generates a sinusoidal output with minimum distortion, allowing power to be supplied to sensitive
apparatus.
High input power factor and low distortion sinusoidal of input current: the high frequency rectifier
or corrector (PFC) which allows the UPS consumes power with a power
factor near to unity and with a low distortion sinusoidal of input current, no matter what type of connected
load to the equipment.
Microprocessor control: All the power conversions are controlled by totally digital signal. Excellent
performance and reliability are realized together with all kinds of protection functions.
Instantaneous transition from normal to battery mode operation and vice versa: as this is a double
conversion model, there is no failure in the output voltage in transitions between mains and battery.
High input voltage range: The rectifier works at mains of low voltages at full load, which prevents energy
from being extracted from the battery even at these voltages.
High efficiency: this UPS range has a high efficiency up to 92%.
Protected against overloads and short-circuits: are fitted with protection circuits that
prevent the device from being damaged by short-circuit or excess load.
Front control panel: in the front of UPS there are LED indicators, a LCD display and a keypad which
indicate the operation mode, mimic diagram, warning and failure information, and allow browsing through
the display to monitor UPS data and necessary settings.
Monitoring software: included RS232 and USB type connections which, by means of software, allows
you to save files, run programmes, turn off the PC, etc., as well as monitoring in real-time the status of the
UPS.
Self-Battery and UPS test: also is included a function that performs a battery and UPS test in order to
check status of them.
Battery test: this series has an option that performs a battery test in order to check the battery status.
3-level intelligent charger: UPS of this series has an intelligent charger of three optimized battery charge
levels to enlarge the lifetime of the batteries.