ā
W
e recommend that you remove dust and stains from time to time with a damp
cloth, because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your dealer for
repairs. When the power cord is damaged, it may only be replaced by an
a
uthorised fitter. Use a new cord of the type H05 VV-F.
N STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using the
heater follow the instructions again
(starting from section A and as specified).
O TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank
6 from the heater and remove the fuel filter
(refer to Section M, Fig. L). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater
.
Place the transportation cap into the position of the fuel filter (Fig. M).
Press it tight.
Always move the heater in an upright position.
P SPECIFICA
TIONS
Ignition
electrical
Dimensions (mm)
width 334
Fuel
paraffin including base plate: depth 300
Capacity (kW) max. 2.70 height 415
Capacity (kW) min. 0.83 Accessories: - manual fuel pump
Suitable space (m
3
)
**
40-105 - transportation cap
Fuel consumption (l/hr)
*
0.281 Mains 230 V
-- AC / 50 Hz
Fuel consumption (g/hr)
*
225
Electrical consumption
:
Bur
ning time per tank (hr)
*
14.2
-
igniter
320 W
Capacity removable tank (litres) 4.0 - continuous 14 W
Weight (kg) 8.9 Fuse rating 250V, 5A
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor E-Guard R).
* At maximum setting **
Specified values ar
e indicative