801981UK - Commercial Chilled,sparkling User manual - Sept. 2016- v3.02 Page 11 of 20
• Press the [MENU] button for main
menu.
• Press the [Install] button.
• Press the [Filter Reset] button.
• Press the [Reset Filter] button.
• If you need to flush the filter follow
the filter flush guide, see page 9.
• To cancel the filter reset program
press [HOME] or [<=].
• To set the filter life or edit filter
usage, see page 14.
After replacing the filter, the counters should be reset.
2. Filter reset
LCD screen operation - section C
3. CO2 purge
4. Lux sensor calibration
• Press the [MENU] button for
main menu.
• Press the [Install] button.
• Press the [Lux Sensor
Calibration] button.
• The lights on the tap head will
flash to confirm calibration.
Note
Correct operation of the Lux sensor can be verified by selecting Lux
Sensor - OFF. When the room is subsequently darkened, below the calibrated
light level, the lights will turn off after 30 seconds.
When fitting a new gas cylinder, it is important to purge the gas lines.
• Press the [MENU] button for main
menu.
• Press the [Install] button.
• Press the [Purge CO2] button.
• In the next screen, press the
[START] button to commence the
purging process.
• Wait for the water to stop flowing
through the unit.
• Wait a further 10 seconds after the
water has stopped running. During
this time you will hear the CO2 gas
running through the tap.
• Press [STOP] to stop the purge.
Zip Chilled Sparkling
Zip Chilled Sparkling
Zip Chilled Sparkling
Zip Chilled Sparkling