Gas Conversion Procedure
Step 2: Surface Burners
To replace the nozzles of the surface burners, lift up the burners and unscrew the
nozzles shipped with the range using a 7 mm (socket wrench).
Replace nozzles using the conversion set supplied with the range. Each nozzle has a
number indicating its flow diameter printed on the body. Consult the table on page 21
for matching nozzles to burners.
NG = Natural Gas
LPG = Liquid Propane Gas
NG LPG
9/32
9/32
Step1
Step 2
Step 3
Step 4