1. Light one burner at a time and set it to the MINIMUM position (small flame).
2. Remove the knob.
3. The range is equipped with a safety valve. Using a small-size flathead screwdriver,
locate the choke screw (see diagram below) and turn to the right or left until the
burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
Flame Adjustment
2.0 x 80 mm
2.0 x 80 mm
Flame Adjustment
The high flame setting cannot be adjusted to be lower. If the height is
too high, revisit the conversion set up. A step may have been missed.