Optional Remote Set-up
Heater Controls Quick Guide
Operating Modes
• Poolorspawillheatonlywhentheltrationsystemis
running and the control has been turned ON for either
POOL or SPA as indicated by a green LED above
either POOL or SPA button.
• MaintainTemperature(Auto-Heat)willallowthe
heatertocheckthepooltemperatureperiodicallyand
overridetimeclocksettings,heatingthepoolorspa
wheneverthetemperaturefallsbelowthesetpoint.
Thisfeatureontheheaterrequiresadditionaleld
wiring and optional relay.
Normal Operation
• WhenZodiac(Z)iconislit,theunithaspower.
Choose Pool or Spa. Each has its own set
temperature.
• TemperaturemayberaisedorloweredusingUPor
DOWN arrow buttons.
Red LED above POOL or SPA button indicates the
unit is heating.
Green LED above POOL or SPA button indicates
theunitisONinpoolorspamodeandheaterhas
reacheddesiredsettemperature.
User Set-up Mode
WiththeunitOFF,pressandholdMENUfor7-10
seconds.UseUP/DOWNarrowkeystotogglebetween
thefunctions.TheMENUkeytogglesvariousoptions
within the functions. Press POOL or SPA button to end
Setup Mode and return to OFF.
User Set-up Functions
1) LanguageSelection.
SelectEnglish,SpanishorFrench.
2) TemperatureScale.
Select Fahrenheit or Celcius scale.
3) SpaTimer.
Providesautomaticshutdownofspaoperation.
4) DisplayLighting.
ControllerlightscanbesetON,OFFortoSHUTOFF
afteratwominutedelay.
Refertotheheaterinstallationandoperationmanual
forcompletedescriptionsofeachfunction.
Service Set-up Mode
WiththeunitOFF,pressMENU,andPOOLbuttonand
SPAbuttonsimultaneously.Holdallthreebuttonsfor
7-10seconds.
TheUP/DOWNarrowkeystogglebetweenthe
differentfunctions.TheMENUkeytogglesvarious
options within the functions. The POOL & SPA keys end
the Setup Mode and return to ‘OFF’.
Service Set-up Functions
1)MaintainTemperature
2)MaintainTemperatureDelay
3) RemoteThermostat
4) FreezeProtect
5) Louver(LXimodelsonly)
6) LoadDefaults-Resetsfactorysettings
7) AirTemperatureCalibration
8) WaterTemperatureCalibration
9) WaterTemperatureDifferential
10) Statistics
11) LastFault
Refertotheheaterinstallationandoperationmanual
forcompletedescriptionsofeachfunction.
Maintain Temp Set-up
Thisfeaturerequiresadditionaleldwiringandan
optionalrelay.FollowdirectionsfromServiceSet-up
Mode(seeabove),MaintainTemperature(Service
Set-UpFunction1).Tooperateinpoolmodewiththe
MaintainHeatfeature,pressPOOL,thenpressMENU,
presstheDownbuttonuntilMAINTAINPOOLHEATis
displayed,thenpresstheMENUbutton.
The green LED indicator lights and the unit will display
SET:XXº.Changethetemperaturesetpointby
pressingtheUPorDOWNbuttonuntilthedesiredset
pointisdisplayed.After5secondsofinactivity,thenew
setpointisstoredinmemory.
Anoptionalcontrolcanbeinstalledremotelywith22AWG
4conductorwireupto300’.Theadditionalcontrolcanbe
wiredinapoolhouseorinthehome.Allwiringmustbedone
in accordance with applicable local and National codes and
requirements.
AquaLink
®
RS/Remote
Wire as shown in Figure 2.
• EnterServiceSet-Upmode(seeright).ChooseRemote
Thermostat(ServiceSetupFunctions#3,seeright).
Display will show REMOTE on the second line.
• UseUP/DOWNarrowstotoggle:‘OFF’,‘HI-LO-COM’,or
‘REMOTET-STAT’.ForAqualinkRSconnectionchoose
’REMOTET-STAT’.
• PressMENUtosaveselection.PresseitherPOOLorSPA
toexitServiceSet-Upmode.
• PressPOOLorSPAbutton,thenUParrowkeyto
raisespatemperaturesetpointtomaximum(104°F).
ControlwillindicateeitherPoolorSpaenabledandash
REMOTET-STATENABLED.
Figure 3.
AquaLink RS 485
Communication
(4-Wire
Connection)
Figure 1.
RemotePool-Off-
Spa Connection
(3-Wire
Connection)
Figure 2.
AquaLink RS or
RemoteTSTAT
Connection
(2-Wire
Connection)
AquaLink RS 485
Wire as shown in Figure 3.
• DisplayshowsJANDYREMOTEONLINEPUSHMENU
TODISABLE.Theheatercontrolpanelisnowdisabled.
• Totemporarilyusetheheatercontrols,pressMENUand
all functionality will return to the heater control.
• ToreturnfunctionalitytotheRSremote,pressMENUfor
5secondstoentertheUserSet-upmodeandthenenable
theremote.
WARNING
TO AVOID PROPERTY DAMAGE, INJURY
OR DEATH, BE SURE TO READ THE
“CONSUMER INFORMATION AND SAFETY”
SECTION IN THE HEATER INSTALLATION
AND OPERATION MANUAL.
LXi Heaters
JXi Heaters
Question and Answer IconNeed help?

Do you have a question about the Zodiac Jandy LXi Pro Series and is the answer not in the manual?

Zodiac Jandy LXi Pro Series Specifications

General IconGeneral
BrandZodiac
ModelJandy LXi Pro Series
CategoryController
LanguageEnglish

Summary

Operating Modes

Maintain Temperature (Auto-Heat)

Configures heater to check pool temp periodically and heat when below set point.

Normal Operation

Explains power status, pool/spa selection, temperature adjustment, and heating indicators.

User Set-up Mode

Language Selection

Allows selection of English, Spanish, or French language.

Temperature Scale

Allows selection of Fahrenheit or Celsius temperature scale.

Spa Timer

Provides automatic shut down of spa operation.

Display Lighting

Sets controller light behavior (ON, OFF, or delayed SHUT OFF).

Service Set-up Mode

Maintain Temperature

Configures automatic heating based on temperature.

Maintain Temperature Delay

Sets a delay for maintaining temperature.

Remote Thermostat

Configures connection to a remote thermostat.

Freeze Protect

Enables or disables freeze protection for the unit.

Load Defaults

Resets the unit to factory default settings.

Air Temperature Calibration

Calibrates the air temperature sensor.

Water Temperature Calibration

Calibrates the water temperature sensor.

Last Fault

Shows the last recorded error or fault.

Set Point Lockout

Example of Set-up for RS Controls