7
Troubleshooting
Problem Solution
Cleaner does not turn
on
Low battery. Charge until battery LED is solid green.
Press down and release the On/off button towards the
symbol to start/stop the cleaner.
Overheated. Move cleaner to cooler area. Do not store above
32°C.
Cleaner does not
charge
No power. Reset circuit breaker. Try plugging charger into a
different outlet.
Dirty connection. Clear debris from plug on cleaner.
Cleaner does not dive
-or- does not move in
water
Trapped air. Hold cleaner under water, tilt and shake to release
air bubbles.
Filter full/dirty. Empty canister, wash with soapy water and a soft
brush.
Make sure the pivot float arm moves freely.
Manually rotate wheels back and forth to release blockage.
Cleaner does not
climb walls -or- does
not reach all areas
Filter full/dirty. Empty canister, wash with soapy water and a soft
brush.
Turn off spa pump and jets while using cleaner.
Water chemistry imbalance. Consult a spa service professional.
Some spa designs may have areas inaccessible to the cleaner.
Lid detaches
unexpectedly
Reattach lid securely (see step in “Empty the Filter Canister”
section).
Latch stuck. See latch problem/solution below.
Latch is difficult to
open -or- does not
stay closed.
Submerge cleaner in water, open and close latch a few times to
rinse out sand.
Completely dry out cleaner, open and close latch a few times,
blow out sand.
Sand / debris escaping
from filter
Remove canister, wash with soapy water and a soft brush.
Make sure canister is seated and oriented properly.
Cleaner floats to the
surface
Normal operation. Cleaner stops and floats when the cleaning
cycle is done.
Normal operation. Cleaner floats periodically during navigation.
Cleaner does not float
to the surface at end
of cycle
Filter very full. Empty filter canister.
Flashing red LED
Blockage detected. Turn off cleaner and remove lid. Clear
debris from exposed moving parts.
If a problem persists, please contact the retailer to request a diagnostic review.