AQUASPEC FAUCETS
MODEL - Z86500 SERIES
CENTERSET METERING
TECHNICAL INFORMATION
FLOW: 0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 SECOND @ 80 PSI ADJUSTABLE
MAXIMUM PRESSURE: 125 PSI
MAXIMUM TEMPERATURE: 180
O
F
F
®
INSTALLATION INSTRUCTIONS
1. THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.
2. REMOVE FAUCET BODY FROM CARTON AND PLACE FAUCET ON SINK.
3. ATTACH MOUNTING NUTS (#7A) ONTO SHANKS FROM UNDER SINK.
4. HAND TIGHTEN MOUNTING NUTS (#7A). DO NOT OVER TIGHTEN, YOU COULD DAMAGE THE FIXTURE.
5. ATTACH LAVATORY SUPPLY TO THE OUTLET OF THE SUPPLY STOP AND CONNECT TO FAUCET WITH RISER NUT
(#7B).
6. OPTIONAL - POP-UP (-P)/ GRID STRAINER (-G)/HANDICAP OFFSET GRID DRAIN (-GH):
INSTALL POP-UP OR GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.
7. TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS
8. INSTALL SPRAY OUTLET (#6) INTO FAUCET AND HAND TIGHTEN.
9. METERING CARTRIDGE IS FACTORY PRESET FOR A 10 SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS
NECESSARY, SEE “ADJUSTING THE FLOW” SECTION (PAGE 2).
PAGE 1 OF 4
*
Form # CF102 Date: 4/2/07
C.N. No. 106044 Rev. M
IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT
FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS AND THEREBY PREVENTING
THE FAUCET FROM FUNCTIONING PROPERLY
IMPORTANTTHE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE METERING
CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET. THE INTEGRAL FILTER MAY BE
REMOVED TO BE BACK-FLUSHED AND CLEANED IF INSUFFICIENT FLOW IS DETECTED. THE INTEGRAL SHANK FILTER
ASSEMBLY MUST BE RE-INSTALLED AFTER SERVICING TO ENSURE PROPER FUNCTIONING OF THE METERING CARTRIDGE.
- CAN USE QUARTER TURN CERAMIC DISK CARTRIDGE
Question and Answer IconNeed help?

Do you have a question about the ZURN AQUASPEC Z86500 Series and is the answer not in the manual?

ZURN AQUASPEC Z86500 Series Specifications

General IconGeneral
BrandZURN
ModelAQUASPEC Z86500 Series
CategoryPlumbing Product
LanguageEnglish

Summary

Technical Information

Flow Rate and Pressure Specifications

Details on GPC, maximum pressure, and temperature limits.

Important Installation Notes

Emphasizes flushing lines and the function of the integral shank filter.

Installation Instructions

Pre-installation Flushing

Instruction to thoroughly flush water supply lines before faucet installation.

Faucet Assembly Steps

Steps for removing faucet, attaching nuts, connecting supply, and installing spray outlet.

Optional Drain Installation

Guidance for installing optional pop-up or grid strainer drains.

Water Turn-on and Leak Check

Procedure for turning on water supply and checking for leaks.

Metering Cartridge Preset

Information on the factory preset for the metering cartridge cycle time.

Maintenance and Adjustment

Cleaning and Finish Care

Recommendations for cleaning the faucet's chrome-plated finish safely.

Metering Cartridge Service

Detailed steps for removing, inspecting, and replacing the metering cartridge.

Filter and Aerator Maintenance

Advice on periodic flushing or replacement of the integral shank filter and aerator.

Adjusting Flow Cycle Time

Instructions on how to adjust the faucet's cycle time using the adjustment nut.

Replacement Parts List

Related product manuals