2 EASY
-7-
Remember to power Off and power On the door station and then flip
DIP-6 ON to perform following settings:
1. Press Key A, Unlock Indicator turns on with double beep sound
2. Press Key A again to set the Unlocking Mode to Normally Open or Normally Closed
Normally Open: Status Indicator blinks once with beep sound
Normally Closed: Status Indicator blinks twice with beep sound
If door station has TFT screen connected, current Unlocking Mode will be visible on the screen
• Unlocking Mode Setting
2. Settings via Invisible Keys A and B
• DIP-4 is for button code selection for Door Stations with buttons. All Buttons are pre-programmed
with User Code/Address (see page 15). If you planning to use factory programming, keep DIP-4
Off. When factory programming going to be modified, change DIP-4 to On position
• DIP-5 is for unlocking time quick setting. Off(0) is the default setting, and the default time is 1
second. If set On(1), the unlock time is 5 seconds (Different unlock time can be programmed,
DIP-5 should be in On position for different times)
• DIP-6 is for activating invisible key A and key B. Power Off door station and power On, then flip
DIP-6 into On position. Remember to flip Off after programming finished.