EasyManua.ls Logo

2N Helios Force - Page 39

2N Helios Force
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2N TELEKOMUNIKACE a.s., www.2n.cz 39/72
Parameter
(function)
Parameter
Name
Range Default Note
932 Automatic
response
speed
0–3 2 3 = Maximum response speed
933 Reception
volume
0–15 7 15 = Maximum reception volume
934 Transmission
volume
0–15 7 15 = Maximum transmission volume
935 Message
volume
0–15 7 15 = Maximum message volume
936 Beeping
volume
0–12 12 12 = Maximum tone volume
937 DTMF
hearing (side
tone)
volume
0–3 3 3 = Maximum DTMF volume
938 Loudspeaker
volume
0–15 7 15 = Maximum loudspeaker volume
941 Minimum
continuous
tone time
10–99 20 = 2 s If the tone is longer, the intercom hangs up.
942
Minimum
busy tone or
pause
duration
0–255
8 = 0,08
s
These parameters control the busy tone
detection. They are used for call termination