EasyManua.ls Logo

2N Helios Force - Page 47

2N Helios Force
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2N TELEKOMUNIKACE a.s., www.2n.cz 47/72
Switch 2 activation (light, e.g.)
The second switch (if an additional switch is installed) can be controlled in the same
way, default password is 11.
Switch 2 synchronisation
Switch 2 can also be used to delay the opening of another door. Once the switch 2
delay timeout is programmed, the second switch is synchronised automatically with
the first one, the delay being 1 – 25 seconds.
Switch activation signalling (for both switches)
After the correct password is entered, the switch is activated and you can hear the
confirmation signal on your telephone. You can now speak (e.g. say: "The door is
open") or listen (to the door-opening sound, etc.) until the switch is deactivated. Upon
deactivation, you can hear the storing signal (see the Signals Overview).
Call extension
The intercom beeps 10 seconds before the call end. To extend the call by 30 seconds
press on your telephone (DTMF). You can use this function repeatedly. The visitor,
however, cannot use this function!
Programming
The access to this mode is password-protected. For details refer to the Programming
section. The voice menu helps you considerably with programming the intercom.
Having entered the programming mode, you can also alter any parameter and
memory settings.
Caution
The above mentioned functions (except for calls to the intercom)
require a telephone settone-dialling .

Table of Contents

Related product manuals