Connect only RJ-45 data connectors, network telephony
systems, or network telephones to these sockets. Either shielded
or unshielded data cables with shielded or unshielded jacks can
be connected to these data sockets.
z Power Cord Set:
The power cord set must be approved for the country where it is used:
U.S.A. and
Canada
z The cord set must be UL-approved and CSA
certified.
z The minimum specifications for the flexible
cord is:
No. 18 AWG
Type SV or SJ
3-conductor
z The cord set must have a rated current
capacity of at least 10A.
z The attachment plug must be an
earth-grounding type with a NEMA 5-15P
(15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
UK
z The supply plug must comply with BS1363
(3-pin 13-amp) and be fitted with a 5 A fuse
which complies with BS1362.
z The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3G1.0(minimum).
Europe
z The supply plug must comply with CEE7/7
(“SCHUKO”)
z The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3G1.0(minimum).
Denmark
The supply plug must comply with Section
107-2-D1, Standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE
1011.